MAX16047ETN+W Maxim Integrated, MAX16047ETN+W Datasheet - Page 48

no-image

MAX16047ETN+W

Manufacturer Part Number
MAX16047ETN+W
Description
Supervisory Circuits 12-Channel EEPROM-Programmable System Manager with Nonvolatile Fault Registers
Manufacturer
Maxim Integrated
Series
MAX16047, MAX16049r
Datasheet

Specifications of MAX16047ETN+W

Number Of Voltages Monitored
12
Undervoltage Threshold
Adjustable
Overvoltage Threshold
Adjustable
Manual Reset
Resettable
Watchdog
Watchdog
Supply Voltage - Max
14 V
Maximum Power Dissipation
3810 mW
Supply Current (typ)
3800 uA
Supply Voltage - Min
3 V
8) The slave asserts an ACK on SDA.
9) The slave sends the 8-bit byte count (16).
10) The master asserts an ACK on SDA.
11) The slave sends 8 bits of data.
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
Figure 12: I
48
S = START CONDITION
P = STOP CONDITION
SR = REPEATED START CONDITION
D.C. = DON'T CARE
______________________________________________________________________________________
WRITE BYTE FORMAT
READ BYTE FORMAT
SEND BYTE FORMAT
BLOCK READ FORMAT
BLOCK WRITE FORMAT
S
S
S
S
S
2
SLAVE ADDRESS:
EQUIVALENT TO CHIP-
SELECT LINE OF A
3-WIRE INTERFACE.
SLAVE ADDRESS:
EQUIVALENT TO CHIP-
SELECT LINE OF A
3-WIRE INTERFACE.
SLAVE ADDRESS:
EQUIVALENT TO CHIP-
SELECT LINE OF A
3-WIRE INTERFACE.
SLAVE ADDRESS:
EQUIVALENT TO CHIP-
SELECT LINE OF A
3-WIRE INTERFACE.
SLAVE ADDRESS:
EQUIVALENT TO CHIP-
SELECT LINE OF A
3-WIRE INTERFACE.
C/SMBus Protocols
ADDRESS
ADDRESS
ADDRESS
ADDRESS
7 BITS
SLAVE
7 BITS
ADDRESS
7 BITS
7 BITS
7 BITS
WR
WR
WR
0
WR
0
0
0
WR
0
ACK COMMAND ACK
ACK COMMAND ACK
ACK
ACK COMMAND ACK
DATA BYTE: PRESETS THE
INTERNAL ADDRESS POINTER
OR REPRESENTS A COMMAND.
COMMAND BYTE:
PREPARES DEVICE
FOR FOLLOWING
READ.
COMMAND BYTE:
PREPARES DEVICE
FOR BLOCK
OPERATION.
ACK = ACKNOWLEDGE, SDA PULLED LOW DURING RISING EDGE OF SCL
NACK = NOT ACKNOWLEGE, SDA LEFT HIGH DURING RISING EDGE OF SCL
ALL DATA IS CLOCKED IN/OUT OF THE DEVICE ON RISING EDGES OF SCL
ACK
COMMAND BYTE:
DESTINATION
ADDRESS
8 BITS
8 BITS
8 BITS
DATA
8 BITS
COMMAND BYTE:
SELECTS REGISTER OR
EEPROM LOCATION
YOU ARE WRITING TO.
COMMAND
8 BITS
ACK
SR
COUNT= N
SR
P
8 BITS
BYTE
ACK
SLAVE ADDRESS:
EQUIVALENT TO CHIP-
SELECT LINE OF A
3-WIRE INTERFACE.
SLAVE ADDRESS:
EQUIVALENT TO CHIP-
SELECT LINE OF A
3-WIRE INTERFACE.
ADDRESS
ADDRESS
SLAVE
7 BITS
7 BITS
DATA BYTE: DATA GOES INTO THE
REGISTER (OR EEPROM LOCATION)
SET BY THE COMMAND BYTE.
ACK
DATA
8 BITS
DATA BYTE: DATA GOES INTO THE REGISTER SET BY THE
COMMAND
WR
WR
DATA BYTE
1
1
8 BITS
1
ACK DATA BYTE NACK
ACK
RECEIVE BYTE FORMAT
ACK
S
DATA BYTE: DATA IS READ FROM THE REGISTER (OR
EEPROM LOCATION) SET BY THE COMMAND CODE
DATA BYTE: DATA COMES
FROM THE REGISTER SET BY
THE COMMAND BYTE.
COUNT= N
ACK
SLAVE ADDRESS:
EQUIVALENT TO CHIP-
SELECT LINE OF A
3-WIRE INTERFACE.
12) The master asserts an ACK on SDA.
13) Repeat steps 11 and 12 up to fifteen times.
14) The master asserts a NACK on SDA.
15) The master sends a STOP condition.
8 BITS
8 BITS
ADDRESS
BYTE
7 BITS
P
DATA BYTE
8 BITS
...
ACK
WR
1
DATA BYTE
ACK
P
ACK
= SDA TRANSISTIONS FROM HIGH TO LOW DURING PERIOD OF SCL
= SDA TRANSISTIONS FROM LOW TO HIGH DURING PERIOD OF SCL
8 BITS
1
DATA BYTE
DATA BYTE: PRESETS THE
INTERNAL ADDRESS POINTER
OR REPRESENTS A COMMAND.
8 BITS
8 BITS
DATA
N
ACK
DATA BYTE
ACK
NACK
8 BITS
...
P
P
MASTER TO SLAVE
SLAVE TO MASTER
ACK
DATA BYTE
8 BITS
N
NACK
P

Related parts for MAX16047ETN+W