MAX8903NETI+ Maxim Integrated, MAX8903NETI+ Datasheet - Page 7

no-image

MAX8903NETI+

Manufacturer Part Number
MAX8903NETI+
Description
Battery Management 2A 1-Cell Li+ DC-DC Charger for USB and Adapter Power
Manufacturer
Maxim Integrated
Series
MAX8903A, MAX8903B, MAX8903C, MAX8903D, MAX8903E, MAX8903G, MAX8903H, MAX8903J, MAX8903Yr
Datasheet

Specifications of MAX8903NETI+

Battery Type
Li-Ion
Output Voltage
5 V
Output Current
1 mA
Operating Supply Voltage
4.1 V to 16 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Charge Safety Timers
Yes
Maximum Power Dissipation
1666.7 mW
Operating Supply Current
2.3 mA
Product Type
Charge Management
Temperature Monitoring
Yes
Uvlo Start Threshold
3.2 V
EP (TDFN
10-µMAX
10-TDFN
12-Thin
only)
QFN
10
11
12
EP
10
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
PIN
PIN
12-UCSP
12-UCSP
C4
C3
C2
C1
B1
A1
A2
A3
A4
B4
C4
C3
C2
C1
A2
A3
A4
B3
B4
B2
B1
A1
Low-Voltage, Dual SPDT, Audio Clickless
_______________________________________________________________________________________
Switches with Negative Rail Capability
NAME
COM1
COM2
CMPO
NAME
COM1
COM2
CMP-
GND
GND
NO2
NO1
NO1
NO2
NC1
NC2
NC1
NC2
V
V
IN1
IN2
IN1
IN2
EP
EP
CC
CC
Analog Switch 1—Common Terminal
Analog Switch 1—Normally Closed Terminal
Digital Control Input for Analog Switch 1. A logic LOW on IN1 connects COM1 to NC1
and a logic HIGH connects COM1 to NO1.
Comparator Inverting Input
Ground
Digital Control Input for Analog Switch 2. A logic LOW on IN2 connects COM2 to NC2
and a logic HIGH connects COM2 to NO2.
Analog Switch 2—Normally Closed Terminal
Analog Switch 2—Common Terminal
Analog Switch 2—Normally Open Terminal
Comparator Output
Positive-Supply Voltage Input
Analog Switch 1—Normally Open Terminal
Exposed pad. Connect to GND.
Positive-Supply Voltage Input
Analog Switch 1—Normally Open Terminal
Analog Switch 1—Common Terminal
Analog Switch 1—Normally Closed Terminal
Digital Control Input for Analog Switch 1. A logic LOW on IN1 connects COM1 to NC1 and
a logic HIGH connects COM1 to NO1.
Ground
Digital Control Input for Analog Switch 2. A logic LOW on IN2 connects COM2 to NC2 and
a logic HIGH connects COM2 to NO2.
Analog Switch 2—Normally Closed Terminal
Analog Switch 2—Common Terminal
Analog Switch 2—Normally Open Terminal
Exposed pad for TDFN package. Connect to GND.
Pin Description (MAX4762/MAX4764/MAX4764A)
Pin Description (MAX4763/MAX4765)
FUNCTION
FUNCTION
7