S1-A-7001 EasySync, S1-A-7001 Datasheet - Page 18

no-image

S1-A-7001

Manufacturer Part Number
S1-A-7001
Description
RS-232 Interface IC 1 port RS232 Can Adapter
Manufacturer
EasySync
Datasheet

Specifications of S1-A-7001

Rohs
yes
Document Reference No.: ES_000008
S1-A-7001 RS232 to 1-Port CANbus Adapter User Guide
Version 1.2
Clearance No.: ES #03
4.1.9 Open CAN Channel (O)
Summary
Opens CAN channel for read/write operations. CAN channel must be initiated with selected speed
(S or s) prior to use of Open.
Definition
O<CR>
Parameters
None
Remarks
Example:
O<CR>
Open CAN channel in normal communication mode.
Once the CAN channel is open, it is necessary to execute the Echo/Synchronize (E or e)
command to flush the data buffers. Once the CAN channel is synchronized, received data is
automatically sent from the CAN network to the controlling application.
Return Codes
<CR> = OK
<BELL> = ERROR
18
©2009-10 EasySync Ltd.