Datasheet

Specifications of MAX5530ETC

Number Of Converters
1
Number Of Dac Outputs
1
Resolution
12 bit
Interface Type
QSPI, SPI, Serial (3-Wire, Microwire)
Settling Time
660 us
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
TQFN EP
Minimum Operating Temperature
- 40 C
Output Type
Voltage
Supply Voltage - Max
5.5 V
Supply Voltage - Min
1.8 V
Voltage Reference
External
Ultra-Low-Power, 12-Bit,
Voltage-Output DACs
Table 2. Serial-Interface Programming Commands
X = Don’t care.
*Standby mode can be entered from normal operation only. It is not possible to enter standby mode from shutdown.
14
C3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
______________________________________________________________________________________
CONTROL BITS
C2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
C1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
C0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
XXXXXXXXXXXX
XXXXXXXXXX
XXXXXXXXXX
XXXXXXXXXX
INPUT DATA
12-bit data
12-bit data
12-bit data
12-bit data
D11, D10,
D11, D10,
D11, D10,
D11–D0
No operation; command is ignored.
Load input register from shift register; DAC register unchanged;
DAC output unchanged.
Command reserved; do not use.
Command reserved; do not use.
Command reserved; do not use.
Command reserved; do not use.
Command reserved; do not use.
Command reserved; do not use.
Load DAC register from input register; DAC output updated;
MAX5530 enters normal operation if in shutdown; MAX5531 enters
normal operation if in standby or shutdown.
Load input register and DAC register from shift register; DAC output
updated; MAX5530 enters normal operation if in shutdown;
MAX5531 enters normal operation if in standby or shutdown.
Command reserved; do not use.
Command reserved; do not use.
MAX5530 enters shutdown; MAX5531 enters standby*. For the
MAX5531, D11 and D10 configure the internal reference voltage
(Table 3).
MAX5530/MAX5531 enter normal operation; DAC output reflects
existing contents of DAC register. For the MAX5531, D11 and D10
configure the internal reference voltage (Table 3).
MAX5530/MAX5531 enter shutdown; DAC output set to high
impedance. For the MAX5531, D11 and D10 configure the internal
reference voltage (Table 3).
Load input register and DAC register from shift register; DAC output
updated; MAX5530 enters normal operation if in shutdown;
MAX5531 enters normal operation if in standby or shutdown.