G6Z-1F-A Omron Corporation, G6Z-1F-A Datasheet
G6Z-1F-A
Available stocks
Related parts for G6Z-1F-A
G6Z-1F-A Summary of contents
Page 1
... Contact Form 1: SPDT 3. Terminal Shape F: Surface mount terminals P: PCB through-hole terminals 4. Terminal Structure None: Y-shape terminal E: E-shape terminal 5. Characteristic Impedance None: 75 Ω 50 Ω Contact Arrangement None: Standard contact arrangement R: Reverse contact arrangement 7. Rated Coil Voltage 3, 4. 12, 24 High-frequency Relay G6Z 1 ...
Page 2
... VDC 50 Ω 12, and 24 VDC Rated coil voltage Model G6Z-1PE G6Z-1PE-A G6Z-1P G6Z-1P-A G6ZU-1PE G6ZU-1PE-A G6ZU-1P G6ZU-1P-A G6ZK-1PE G6ZK-1PE-A G6ZK-1P G6ZK-1P-A Rated coil voltage Model G6Z-1FE G6Z-1FE-A G6Z-1F G6Z-1F-A G6ZU-1FE G6ZU-1FE-A G6ZU-1F G6ZU-1F-A G6ZK-1FE G6ZK-1FE-A G6ZK-1F G6ZK-1F-A ...
Page 3
... The operating characteristics are measured at a coil temperature of 23° C. Non-latching, Standard and Reverse-contact Models Rated Rated voltage current (VDC) (mA) 3 66.7 4.5 44.4 5 40.0 9 22.2 12 16.7 24 8.3 Single Coil Latching Models G6ZU-1P(E), G6ZU-1F(E) Rated Rated voltage current (VDC) (mA) 3 66.7 4.5 44.4 5 40.0 9 22.2 12 16.7 24 8.3 900 MHz Through hole ...
Page 4
... Dual Coil Latching Models G6ZK-1P(E), G6ZK-1F(E) Rated Rated voltage current (VDC) (mA) 3 120 4 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23° C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23° C. ...
Page 5
... MHz switching frequency of 1,800 operations/hour Operating: -40° 70° C (-40° 158° F) (with no icing or condensation) Operating 85% RH Approx. 2.8 g Ambient Temperature vs. Must Operate or Must Release Voltage 100 Max. estimated value Sample: G6Z-1P 5 VDC 90 Number of relays: 5 max avg. min. ...
Page 6
... Operating frequency (×10 3 operations) Electrical Endurance (Contact Resistance) 1,000 Sample: G6Z-1PE 75 Ω 5 VDC NO 700 contact Number of Relays Test conditions resistive load 500 contact at 30 VDC Switching frequency: 1,800 operations/h 300 max. 100 max. 70 ...
Page 7
... Must release bounce time 25 Sample: G6Z-1P 75 Ω 5 VDC 20 Number of Relays 0.5 1.0 1.5 2.0 Time (ms) High-frequency Characteristics at 75 Ω (Return Loss, V.SWR) (Average value (initial value)) 0 Sample: G6Z-1PE 75 Ω 5 VDC with terminating resistance 10 Return loss V.SWR 50 60 N.O. N. 500 1,000 1,500 2,000 2,500 3,000 Frequency (MHz) High-frequency Characteristics at 50 Ω ...
Page 8
... Mounting Dimensions (Bottom View) Tolerance: ±0.1 mm Nine, 1.8-dia. Nine, 1.0-dia. holes 7.62 2.54 7.62 15.24 0.18 Terminal Arrangement/Internal Connections (Bottom View) G6Z-1PE Orientation mark 1 7 − G6Z-1PE-R Orientation mark 1 7 − G6ZU-1PE Orientation mark 1 7 − − ...
Page 9
... Seven, 1.0-dia. holes 7.62 Three, 1.6-dia. Three, 0.8-dia. holes 2.54 7.62 15.24 0.18 Terminal Arrangement/Internal Connections (Bottom View) G6Z-1P Orientation mark − G6ZU-1P Orientation mark − − Terminal Arrangement/Internal Connections (Bottom View) G6Z-1P-A Orientation mark ...
Page 10
... Note: Each value has a tolerance of ±0.3 mm. G6ZK-1P-A 20 8.6 8.9 3 2.54 12-0.6 0.2 (Coil 7.62 7.62 terminal) 15.24 Note: Each value has a tolerance of ±0.3 mm. G6Z 10 High-frequency Relay Mounting Dimensions (Bottom View) Tolerance: ±0.1 mm Ten, 1.8-dia. Ten, 1.0-dia. holes 7.62 2.54 7.62 15.24 0.18 Mounting Dimensions (Bottom View) Tolerance: ±0.1 mm Nine, 1.8-dia. Nine, 1.0-dia. holes 7 ...
Page 11
... Orientation mark − − Terminal Arrangement/Internal Connections (Top View) G6Z-1FE-A Orientation mark − G6ZU-1FE-A Orientation mark − − Terminal Arrangement/Internal Connections (Top View) G6Z-1F Orientation mark − ...
Page 12
... Tolerance: ±0.1 mm 15.24 2.3 2.54 8.3 Eleven, 1.1 7.62 0.18 Mounting Dimensions (Top View) Tolerance: ±0.1 mm 15.24 7.62 2.54 2.3 0.8 0.8 0.8 8.3 0.18 Seven, 1.1 Mounting Dimensions (Top View) Tolerance: ±0.1 mm 15.24 7.62 2.3 2.54 8.3 Ten, 1.1 0.18 Terminal Arrangement/Internal Connections (Top View) G6Z-1F-A Orientation mark − G6ZU-1F-A Orientation mark − − ...
Page 13
... Mounting Dimensions (Top View) Tolerance: ±0.1 mm 15.24 7.62 2.3 2.54 8.3 Twelve, 1.1 0.18 Terminal Arrangement/Internal Connections (Top View) Orientation mark − + − Terminal Arrangement/Internal Connections (Top View) Orientation mark − + − G6Z High-frequency Relay 13 ...
Page 14
... Relays in stick packing will be provided. Relays per Reel: 300 Direction of Relay Insertion Pulling direction Top tape (cover tape) Carrier tape Emboss tape Reel Dimensions A 330 80 G6Z 14 High-frequency Relay Carrier Tape Dimensions 16 ±0.1 ±0.1 4 ±0.1 2 Stopper (green) ±0.1 10.2 4 ± ...
Page 15
... OMRON’s recommended PCB pattern. Correct Soldering Incorrect Soldering Relay Insufficient Terminal amount of Solder PCB solder Land Check the soldering in the actual mounting conditions before use Soldering Time Maximum peak (T4) 250° C max. 255° C max. Excessive amount of solder G6Z High-frequency Relay 15 ...
Page 16
... Please observe the following precautions to prevent failure to oper- ate, malfunction, or undesirable effect on product performance. High-frequency Characteristics Measurement Method and Measurement Substrate High-frequency characteristics for the G6Z are measured in the way shown below. Consult your OMRON representative for details on 50- Ω models. Measurement Method for 75-Ω Models G6Z ...
Page 17
... Latching Relay may be set accidentally. Be sure to apply a reset signal before use. Coating Do not use silicone coating to coat the Relay when it is mounted to the PCB. Do not wash the PCB after the Relay is mounted using detergent containing silicone. Otherwise, the detergent may remain on the surface of the Relay. High-frequency Relay G6Z 17 ...
Page 18
... Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference. (b) Use in consumer Products or any use in significant quantities. G6Z 18 High-frequency Relay (c) Energy control systems, combustion systems, railroad systems, aviatio medical equipment, amusement machines, vehicles, safety equipment, installations subject to separate industry or government regulations ...
Page 19
... Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information. OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Specifications subject to change without notice High-frequency Relay Printed in USA G6Z 19 ...