Q67000-A9096 SIEMENS [Siemens Semiconductor Group], Q67000-A9096 Datasheet - Page 4

no-image

Q67000-A9096

Manufacturer Part Number
Q67000-A9096
Description
3-A DC Motor Driver
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet
Functional Truth Table
E1
L
L
H
H
Notes for Output Stage
Symbol
L
H
Z
result in turn-OFF of the output stages after a delay of 40 s and setting of the error flag
EF to ground. Changing the inputs resets the error flag.
Output Shorted to Ground Detection
If a high side transistor is switched on and its output is shorted to ground, the output
current is limited to typ 8 A. After a delay of 40 s all outputs will be switched off and the
error flag EF is set to ground.
Monitoring Functions
An internal circuit ensures that all output transistors are turned-OFF if the supply voltage
is below the operating range.
A monitoring circuit for each output transistor detects whether the particular transistor is
active and in this case prevents the corresponding source transistor (sink transistor) from
conducting in sink operation (source operation). Therefore no crossover currents can
occur. Pulse-width operation is possible up to a maximum switching frequency of 1 kHz
for any load.
Depending on the load current higher frequencies are possible.
Protective Function
Various errors like short-circuit to +
Semiconductor Group
E2
L
H
L
H
Q1
H
L
L
Z
Value
Low side transistor is turned-ON
High side transistor is turned-OFF
High side transistor is turned-ON
Low side transistor is turned-OFF
High side transistor is turned-OFF
Low side transistor is turned-OFF
Q2
L
H
L
Z
Comments
Motor turns counterclockwise
Motor turns clockwise
Brake; both low side transistors turned-ON
Open circuit detection
V
S
, ground or across the load are detected. All faults
4
TLE 5203
1998-02-01