Description
ESD Protector Overvoltage Protection Device
Manufacturer
MACOM [Tyco Electronics]
Datasheet
308 Constitution Drive
Menlo Park, CA 94025-1164
Phone: 800-227-4856
www.circuitprotection.com
APPLICATIONS
MATERIALS INFORMATION
PART NUMBERING
The operating voltage is used to measure leakage current @ 1s
Series
EIA Size
BENEFITS
ROHS Compliant
FEATURES
• Suitable for high speed data transmission applications
• Board space savings
• Help to protect sensitive electronic circuits against damage from electrostatic discharge (ESD) events
• Assist equipment to pass IEC 61000-4-2, level 4 testing
• Thick film technology
• Low capacitance (0.25 pF typical)
• Low clamping voltage
• Capable of withstanding numerous ESD strikes
• Compatible with standard reflow installation procedures
• Bi-directional protection
• Cellular phones
Caution: This part is not intended to be used under bias, nor for application with a power bus.
PESD 0603 - 140
Not to be used for new designs. For new designs please use PESD0603-240.
Specification Status: Released
Operating Voltage Designator
14 x 10
ELV Compliant
Raychem Circuit Protection Products
Overvoltage Protection Device
0
= 14V
ESD Protector
DC
PRODUCT: PESD0603-140
DOCUMENT: SCD 26107
REV LETTER: K
REV DATE: DECEMBER 7, 2007
PAGE NO.: 1 OF 7

Related parts for PESD0603-140_07

PESD0603-140_07 Summary of contents

Page 1

... Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com Specification Status: Released Not to be used for new designs. For new designs please use PESD0603-240. BENEFITS • Suitable for high speed data transmission applications • Board space savings • Help to protect sensitive electronic circuits against damage from electrostatic discharge (ESD) events • ...

Page 2

... Value 350 Note 1: IEC61000-4-2, level 4, 8kV contact test method Note 2: TLP test method at 1000V (refer to graph on next page) Note 3: PESD0603-140 can be used only in application without DC bias GENERAL CHARACTERISTICS Operating temperature: -55°C … + 110°C Storage temperature: ESD voltage capability (tested per IEC 61000-4-2) ...

Page 3

... TYPICAL TRANSMISSION LINE PULSE RESPONSE GRAPH 500.00 450.00 400.00 350.00 300.00 250.00 200.00 150.00 100.00 50.00 0.00 0.00 10.00 20.00 ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products 30.00 40.00 50.00 60.00 Time (ns) PRODUCT: PESD0603-140 DOCUMENT: SCD 26107 REV LETTER: K REV DATE: DECEMBER 7, 2007 PAGE NO 70.00 80.00 90.00 100.00 ...

Page 4

... (Ref) Min Max Min 0.5 0.6 1.0 (0.020) (0.024) (0.039) PRODUCT: PESD0603-140 DOCUMENT: SCD 26107 REV LETTER: K REV DATE: DECEMBER 7, 2007 PAGE NO Width D MIN MAX MIN MAX 0.1 0.5 0.6 0.9 (0.02) (0.024) (0.035 Max Min Max 1 ...

Page 5

... Main at 220°C heating at 240°C at 260°C From main heating Cooling temperature to 100°C PRODUCT: PESD0603-140 DOCUMENT: SCD 26107 REV LETTER: K REV DATE: DECEMBER 7, 2007 PAGE NO 30s to 60s 60s to 120s 20s to 40s 60s ~ 70s 50s ~ 60s ...

Page 6

... 13.0±0.5 21.0±0.8 62.0±1 1.75±0.1 2.0±0.05 4.0±0.1 The trailer is 350mm in length & consists of empty cavities with sealed cover tape. PRODUCT: PESD0603-140 DOCUMENT: SCD 26107 REV LETTER: K REV DATE: DECEMBER 7, 2007 PAGE NO Standard Box 25,000 9.0±0.5 13.0±1 1.5± ...

Page 7

... For in-line washing, the temperature of the water sprayed should be at 110°C, rinse and drying is done in-line. Warning: Application Limitations for PESD0603-140. This part is not intended to be used under bias, nor for power bus applications. Users should independently evaluate the suitability of and test each product selected for their own applications Information furnished is believed to be accurate and reliable ...

Related keywords