Current Transducer HX 03..50-P/SP2
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
061026/5
Primary nominal
V
R
R
V
I
V
V
V
X
V
V
TCV
TCV
t
BW
T
T
m
dCp
Notes :
C
r
current rms
A
S
OUT
C
d
e
W
OE
OH
OUT
L
L
Accuracy-Dynamic performance data
Electrical data
General data
I
PN
10
15
20
25
50
OE
OUT
3
5
(A)
1)
2)
With R
Small signal only to avoid excessive heating of the magnetic core
Ambient operating temperature
Ambient storage temperature
Mass
Creepage distance
Isolation material group
Standards
Output voltage (Analog) @ ± I
Output internal resistance
Load resistance
Supply voltage (± 5 %)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
Partial discharge extinction voltage rms @ 10 pC
Impulse withstand voltage, 1.2/50 µs
Accuracy @ I
Linearity error (0 .. ± I
Electrical offset voltage @ T
Hysteresis offset voltage @ I
after an excursion of 1 x I
Temperature coefficient of V
Temperature coefficient of V
Response time to 90% of I
Frequency bandwidth (- 3 dB)
measuring range
Primary current,
L
=2k
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
I
± 9
± 15
± 30
± 45
± 60
± 75
± 150
PM
(A)
PN
, T
1)
A
= 25°C (excluding offset)
Primary conductor
diameter x turns
PN
0.6d x 20T
0.8d x 12T
1.1d x 6T
1.4d x 4T
1.6d x 3T
1.6d x 2T
1.2 x 6.3 x 1T
)
PN
(mm)
PN
A
PN
OE
OUT
P
= 25°C
step
, R
= 0;
2)
(% of reading)
L
= 2 k , T
HX 03-P/SP2
HX 05-P/SP2
HX 10-P/SP2
HX 15-P/SP2
HX 20-P/SP2
HX 25-P/SP2
HX 50-P/SP2
A
= 25°C
Type
V
< 50
+ 12 .. 15
< 15
> 3
< ± 1
< ± 1
+ 2.5V ± 50 mV
< ± 10
< ± 1.5
± 0.1
50
- 25 .. + 85 °C
- 25 .. + 85 °C
8
I
EN50178: 1997
OE
2
1
6
3
5.5
± 0.625
RoHS since
date code
planned
46128
46019
45352
46133
46233
46152
% of I
% of I
mV/K
%/K
m m
kHz
mA
mV
k
µs
kV
kV
kV
PN
PN
V
V
g
Features
Special feature
Advantages
Applications
Application domain
I
PN
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range(3x I
Insulated plastic case recognized
according to UL94-V0.
Single supply from +12V to +15V
Low insertion losses
Easy to mount with automatic
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
Industrial
= 3 .. 50 A
www.lem.com
Page 1/2