MEASURING PRINCIPLE
The transit-time technique uses a pair of sensors with each
sensor sending and receiving ultrasonic signals obliquely
through the fluid.
CONFIGURATION
(1) Single-path system (V method)
(2) Single-path system (Z method)
(3) When using synchronization
<Dedicated Signal cable>
1 2 3 4 5 6 7 8
F
L
Downstream-side sensor
Y
Velocity V
3
4
0
0
0
0
0
Sensor
0
1
1
2
3
Detector
Detector
Detector
Detector
5
0
5
0
0
θ
Upstream-side sensor
1
1
t
Type (4th digit)
Heat-resistant cable with one-side
waterproof BNC connector for FLSE12
and FLSE22
Heat-resistant cable for FLSE31 and FLSE41
Cable length (5th to 7th digit)
5m
10m
15m
20m
30m
Modification No. (8th digit)
Mark 1
2
t
1
Signal cable
Signal cable
Signal cable
Signal cable
Description
D
transmitter
transmitter
(Master)
Flow transmitter
Flow transmitter
(Slave)
Flow
Flow
Flow transmitter
Synchronization
Analog output
Contact output
4 to 20mA DC
Contact
signals
4 to 20mA DC
Contact
signals
4 to 20mA DC
Contact
signals
4 to 20mA DC
Contact
signals
CODE SYMBOLS
<Flow Transmitter>
(Note) This type has not so tough endurance against aera-
<Detector>
(Note) Imcase FLSE 2, select silicon rubber (A) for acous-
F L R E
F L S E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
E
E
tion as Fuji’s general use ultrasonic flowmeters TIME
DELTA-S/F (Model: FLV/FLH) and PORTAFLOW-X
(Model: FLC). For applications containing air bub-
bles, those general use flowmeters are recommend-
able to be used.
tic coupler in ordinary cases. Silicon rubber is sup-
plied in a tube (100g). If one or more detectors are
ordered, silicon rubber may be selected once every
5 orders or so.
Select silicon-free grease (B) for the use in an envi-
ronment where generation of silicon is not desirable
such as semiconductor manufacturing facilities. The
silicon-free grease is soluble in water. Therefore,
do not use it in an environment subject to splash of
water or where condensation tends to occur on the
surface of the piping. The grease, which does not
become hardened, requires periodic maintenance
(cleaning and refilling of about once in 6 months at
room temperature).
2
3
4
1
2
3
4
A
B
C
Y
2
2
1
1
Y
A
A
B
Y
2
2
3
3
1
1
Y
9 10 11 12
9 10
A
B
Y
B
*1) When the 9th digit in the code symbol is “A”,
Y
A
B
C
A
B
the applicable piping diameter is 50 to 150mm.
Type (4th digit)
Standard
Kind of detector (5th to 6th digit)
Small-dia. detector (ø25 to ø100 mm)
Small detector (ø50 to ø225 mm) *1
Small detector (ø50 to ø300 mm)
Small detector (ø300 to ø600 mm) Z method
Acoustic coupler (7th digit) (Note)
None
Silicon rubber
Silicon-free grease
Modification No. (8th digit)
Mark 2
Option (10th digit)
Without
Tag plate
(Fluid temperature: -20 to +100 deg.C)
(Fluid temperature: 0 to +60 deg.C)
Type (4th digit)
Standard for exports
Power Supply (5th digit)
100 to 120Vac, 50/60Hz
200 to 240Vac, 50/60Hz
20 to 30Vdc
Communication and
Synchronization (6th digit)
None
RS-232C
RS-485 and Synchronization
Synchronization
Arrester (7th digit)
None
With arresters for outputs
Modification No. (8th digit)
Mark 2
Case structure (9th digit)
Jetproof type (IP65)
Mounting bracket (10th digit)
For 2B pipe mount
For wall mount
Parameter setting, tag plate (11th digit)
Without
With setting
With setting (Tag plate)
With Tag plate
Detector (12th digit)
FLSE12, FLSE22
FLSE31, FLSE41
Description
Description
V
method
5

Related parts for EDS6-123I