EDS6-121A FUJI [Fuji Electric], EDS6-121A Datasheet - Page 4

no-image

EDS6-121A

Manufacturer Part Number
EDS6-121A
Description
VORTEX FLOWMETER (Eggs DELTA)
Manufacturer
FUJI [Fuji Electric]
Datasheet
4
INSTRUMENTAL DEVIATION AND
PRESSURE LOSS [FIG. 1]
LOAD RESISTANCE RANGE [FIG. 3]
FMP, M
1,550
600
300
-10
10
- 5
5
0
0
0
10
15
25
8
20
12
Power voltage (VDC)
30
Flow rate (%)
40
3% of full-scale measurement
50
24
Water
60
Operation range
70
Air
80
37
90 100
45
39.2
29.4
19.6
9.8
STRAIGHT PIPE LENGTH [FIG. 2]
As a rule, secure the straight pipe length of at least 7D up-
stream and 3D downstream (D: Flowmeter inner diameter).
For actual straight pipe length, see table below.
Pay attention to following items for securing the accuracy.
(1) Use a connecting pipe of an inner diameter same as or
(2) If there is “abrupt expansion of piping diameter” up-
(3) Provide a regulating valve downstream the flowmeter.
8 (SCS14A)
diameter
Nominal
8 (PPS)
more than that of main body.
stream the flowmeter such as metering valve, diffuser,
etc., get at least 50D away.
(mm)
15
25
4
diameter
D: Internal diamete of flowmeter pipe
Inner
(mm)
24.5
8.5
8.5
13
14
L2
Upstream (L1)
171 or more
59 or more
91 or more
59 or more
98 or more
(mm)
Eggs DELTA
L1
Input
direction
Downstream (L2)
25 or more
39 or more
25 or more
42 or more
73 or more
(mm)

Related parts for EDS6-121A