EDS6-119 FUJI [Fuji Electric], EDS6-119 Datasheet - Page 5

no-image

EDS6-119

Manufacturer Part Number
EDS6-119
Description
E SERIESE ELECTROMAGNETIC FLOWMETER(INTEGRAL TYPE)
Manufacturer
FUJI [Fuji Electric]
Datasheet
CODE SYMBOLS
Integral type electromagnetic flowmeter (wafer type)
F
1 2 3 4 5 6 7 8
M E
1
A
D
G
S
C
T
E
F
T
P
H
0
1
-
H
H
9
10 11 12
0
0
1
7
A 0
A
13
0
-
Note 1) Items with the asterisk mark
14
Y
A
B
C
Meter size (5th code)
3A
6A
15A
25A
40A
50A
80A
100A
Lining material (6th code)
TFE (adhesive Tefron) : applied for meter size 15A to 100A
PFA (mold Tefron) : applied for meter size 3A to 6A
Earth ring material (7th code)
None
Hasteroy C
Electrode matertal (9th code)
Hasteroy C
Flange (10th code)
None
Guide ring (11th code)
For JIS 10K
For JIS 75M
Wiring connection port size (12th code)
G1/2(PF1/2) female screw with water-proof gland
(13th code)
None
Optional specifications (14th code)
None
Stainless tag plate
Parameter setting
Parameter setting and stainless tag plate
(Meter size 80A, 100A only)
Description
will be manufactured as order.
5

Related parts for EDS6-119