EMERSON-NETWORKPOWER [Emerson Network Power]
Output Module Voltage/Current
Non-std**
*Note: Contact Factory for extended range down to 6 V.
**Increments of current not shown can be achieved by paralleling modules
(add currents of each module selected).
***Total output power on dual module must not exceed 144 W.
**** For single output modules only.
Ordering Information
Voltage
Case Size (mm)
4 = 2.5” x 5” x 10”; 750 W-1100 W, 5 Slots
8 = 2.5” x 7” x 10”; 1000 W-1200 W, 6 Slots
1 = 2.5” x 8” x 11”; 1200 W-1500 W, 7 Slots
*Note: Add “E” after iMP4 to denote IEC
input option. e.g. iMP4E
(Not available on iMP8 or iMP1)
2.2 V
3.3 V
5.2 V
5.5 V
6.0 V
8.0 V
10 V
11 V
12 V
14 V
15 V
18 V
20 V
24 V
28 V
30 V
33 V
36 V
42 V
48 V
54 V
60 V
2 V
3 V
5 V
(63.5 x 127 x 254)
(63.5 x 177.8 x 254)
(63.5 x 203.2 x 279.4)
Voltage
Code
M
W
D
G
H
N
O
Q
U
A
B
C
E
K
P
R
S
T
V
X
Y
Z
F
L
I
J
iMP1*
Case Size
10.5 A
8.5 A
6.7 A
6.5 A
6.2 A 10.9 A 22.7 A
5.8 A
4.2 A
4.0 A
3.7 A
3.5 A
35 A
35 A
35 A
35 A
35 A
35 A
34 A
23 A
20 A
18 A
17 A
17 A
14 A
14 A
11 A
1
Single Output Module Code
7.5 A
7.5 A
6.0 A
6.0 A
60 A
60 A
60 A
60 A
60 A
60 A
58 A
42 A
36 A
32 A
31 A
30 A
21 A
20 A
19 A
18 A
15 A
11 A
11 A
10 A
2
97.5 A
84.4 A
62.5 A
53.5 A
41.6 A
37.5 A
26.8 A
20.8 A
15.6 A
13.9 A
12.5 A
150 A
150 A
150 A
150 A
150 A
144 A
136 A
50 A
75 A
68 A
30 A
25 A
16 A
3
Special Voltage - Consult Factory for specifications
- 3L0 - 2E2 - 1Q1 - 4LL0 -
136.3 A 10 A
83.3 A
62.5 A
53.5 A
35.8 A
35.8 A
35.7 A
31.2 A
27.7 A
140 A 10 A* 10 A*
140 A
140 A
125 A
107 A
100 A
75 A
50 A
25 A
Module Codes
Module/voltage/option codes
Module codes:
(None) = 36 W triple O/P (1 slot)
1 = 210 W single O/P (1 slot)
2 = 360 W single O/P (2 slot)
3 = 750 W single O/P (3 slot)
4 = 144 W dual O/P (1 slot)
5 - 9 = future
Voltage Codes:
See Output Module Voltage/
Current table above
Option Codes:
0 = Standard
1 = Module enable
2 = Constant current
3 = 1 & 2 combined
4 = Set for use in standard
5 - 9 = Future
5
Module/Voltage/Option Codes
(non-intelligent case)
Second - Voltage Code
Dual Output***
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
Third - Option Code
First - Module Code
9 A
8 A
4 A
3 A
4
10 A
10 A
10 A
10 A
10 A
10 A
10 A
4 A
4 A
4 A
4 A
4 A
4 A
2 A
2 A
4
1 A
1 A
1 A
1 A
1 A
1 A
-
Triple Output
0.5 A
0.5 A
0.5 A
0.5 A
1 A
1 A
1 A
1 A
1 A
1 A
-
0.5 A
0.5 A
0.5 A
0.5 A
Case Option Codes
First digit
0 - 9 = parallel code
(See Parallel Codes table above)
Second digit
0 = No options
1 = Reverse air
3 = Global enable
4 = Fan off w/inhibit
5 = Opt 1 + Opt 3
6 = Opt 1 + Opt 4
7 = Opt 3 + Opt 4
8 = Opt 1 +3 +4
9 = Future
2 A
2 A
2 A
2 A
2 A
2 A
2 A
2 A
1 A
1 A
1 A
1 A
1 A
1 A
-
Case Option Codes
Ranges****
Adjustment
1.8 - 2.2
2.0 - 2.4
2.7 - 3.3
3.0 - 3.6
4.5 - 5.5
4.7 - 5.7
5.0 - 6.1
5.4 - 6.6
7.2 - 8.8
9.0 - 11.0
9.9 - 12.1
10.8 - 13.2
12.6 - 15.4
13.5 - 16.5
16.2 - 19.8
18.0 - 22.0
21.6 - 26.4
25.2 - 30.8
27.0 - 33.0
29.7 - 36.3
32.4 - 39.6
37.8 - 46.2
43.2 - 52.8
48.6 - 59.4
54.0 - 66.0
00
I
2
C
Ordering Note:
1. The cases and modules of both MP and iMP
2. USB to I
Parallel Codes
7
series can be interchanged to allow more
flexibility. If intelligent modules are used
with non-intelligent cases, a numeric code
“4” is placed at the end of the module code
(ex. 4LL0 becomes 4LL4).
-
6
Software code
used for configura-
tion change. “A” is
standard
Embedded Power for
Business-Critical Continuity
Software Code
5 4
2
C module order code 73-769-001
A
3
2
1
-
iMP4
available slots
iMP8
iMP1
0 = no parallel
1 = 1 & 2
2 = 2 & 3
3 = 3 & 4
4 = 4 & 5
5 = 3 & 4 & 5
6 = 5 & 6
7 = 4 & 5 & 6
8 = 6 & 7
9 = 3 & 4, 6 & 7
Factory assembled
for hardware of
firmware mods.
available slots
available slots
Hardware Code
###
Rev. 7.9.09_77
iMP Series
 of 9

Related parts for IMP8-3L0-2E2-1Q1-4LL010-A