5. Uniformity between video signal channels
6. Dark signal
7. Dark signal shading
8. Line crawl
9. Lag
After measuring 4, measure the maximum (Rmax [mV]) and minimum (Rmin [mV]) values of the R signal
and the maximum (Bmax [mV]) and minimum (Bmin [mV]) values of the B signal, and substitute the values
into the following formula.
∆Srg = (Rmax – Rmin)/150
∆Sbg = (Bmax – Bmin)/150
Measure the average value of the signal output (Vdt [mV]) with the device ambient temperature 60°C and
the device in the light-obstructed state, using the horizontal idle transfer level as a reference.
After measuring 6, measure the maximum (Vdmax [mV]) and minimum (Vdmin [mV]) values of the dark
signal output and substitute the values into the following formula.
∆Vdt = Vdmax – Vdmin [mV]
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Gr
signal output is 150mV, and then insert R, G, and B filters and measure the difference between G signal
lines (∆Glr, ∆Glg, ∆Glb [mV]) as well as the average value of the G signal output (Gar, Gag, Gab).
Substitute the values into the following formula.
Lci =
Adjust the Gr signal output value generated by strobe light to 150mV. After setting the strobe light so that
it strobes with the following timing, measure the residual signal (Vlag). Substitute the value into the
following formula.
Lag = (Vlag/150)
∆Gli
Gai
Strobe light
Output
timing
100 [%] (i = r, g, b)
VD
V2
100 [%]
100 [%]
100 [%]
Light
Gr signal output 150mV
– 11 –
Vlag (Lag)
ICX084AK

Related parts for ICX084