LUCW3030ACA AGERE [Agere Systems], LUCW3030ACA Datasheet - Page 8

no-image

LUCW3030ACA

Manufacturer Part Number
LUCW3030ACA
Description
W3030 3 V Dual-Mode IF Cellular Receiver
Manufacturer
AGERE [Agere Systems]
Datasheet
W3030 3 V Dual-Mode IF Cellular Receiver
Operating Ranges
Performance is not guaranteed over the full range of all conditions possible within this table. However, this table
lists the ranges of external conditions in which the W3030 provides general functionality, which may be useful in
specific applications, without risk of permanent damage. The conditions for guaranteed performance are
described below.
Table 3. W3030 Operating Ranges
Electrical Specifications
The following apply to all specifications, unless otherwise listed: T
PIF1
Table 4. dc and Logic Parameters
8
Supply Voltage
First IF Mixer/Amplifier Section:
Digital Second IF Amplifier, AGC Quadrature Demodulator Section:
Analog Second IF Amplifier Frequency
VCM Input Range
Supply Current:
V
V
I
I
Enable Time (external capacitor dependent)
ILMAX
IHMAX
IHMIN
ILMAX
Input Frequency Range
LO Frequency
LO Input Level Range
Second IF Frequency
Quadrature Demodulator LO (CLK) Frequency
CLK Input Level (square wave)
Fully Enable (V
Analog Only Mode (V
Digital Only Mode (V
Sleep Mode (V
LO
(V
(V
= –3 dBm to +3 dBm/50
I
I
= 0.7 V)
= V
CC
)
Parameter
CC
CC
= 3.3)
= 3.3)
CC
CC
= 3.3)
= 3.3)
Parameter
; IF1 = 10 MHz to 200 MHz; IF2 = 0.2 MHz to 2 MHz; ENBA = ENBD > 1.9 Vdc.
Min
1.9
Typ
<1
30
30
8
5
5
0
A
= 25 °C ± 3 °C; V
1.25
Max
Min
–10
–10
250
2.7
0.1
0.4
0.1
0.7
10
10
11
10
10
8
8
CC
V
CC
1000
1000
= 2.7 Vdc;
Lucent Technologies Inc.
Max
4.1
Unit
16
mA
mA
mA
µA
µA
µA
6
4
6
4
µs
– 0.8
V
V
Data Sheet
dBm/50
dBm/50
April 1999
Unit
MHz
MHz
MHz
MHz
MHz
Vdc
V

Related parts for LUCW3030ACA