LUCL8576BP-D AGERE [Agere Systems], LUCL8576BP-D Datasheet - Page 18

no-image

LUCL8576BP-D

Manufacturer Part Number
LUCL8576BP-D
Description
Dual Ringing SLIC
Manufacturer
AGERE [Agere Systems]
Datasheet
L8576B Dual Ringing SLIC
Applications
dc Design
Off-Hook Detection
The loop closure comparator has built-in longitudinal
rejection, eliminating the need for an external 60 Hz fil-
ter. The loop closure detection threshold is internally
set at 12 mA.
Power Ringing
The L8576B is designed to generate a balanced trape-
zoidal power ring signal to tip and ring. Because the
L8576B generates the power ringing signal, no ring
relay is needed in this mode of operation. Alternatively,
the L8576B SLIC can be used in a battery-backed,
unbalanced ringing application. In this case, the ring
signal is generated by a central ring generator and is
bused to individual tip/ring pairs. A ringing relay is used
during ringing to disconnect the L8576B from, and
apply the ring generator to, the tip and ring pair.
This section discusses in detail the use of the L8576B
in the balanced mode of operation.
Crest Factor
The balanced ring signal is generated by simply tog-
gling between the powerup forward and reverse battery
states. The state change is done by applying a square
wave (whose frequency is the desired ring frequency)
to logic input B2. Capacitors CF1 and CF2 and resistor
R
sition of the battery reverse, thus shaping the balanced
ring signal. Setting capacitor CF1 = CF2 = 0.22 F and
setting R
for a 20 Hz ring frequency. This satisfies the Telcordia *
GR-909 requirement of ringing waveform crest factor
between 1.2 and 1.6. Crest factor is defined as the
peak to rms voltage ratio of the ring signal. Ringing
waveforms of crest factors 1.6 and 1.2 are shown in
Figures 18 and 19. The crest factor can be adjusted by
the value of R
value of V
be changed because these affect the dc feedback loop
stability in current limit. An R
lower the crest factor to about 1.2 with a –65 V or
–72 V battery for a 20 Hz ring frequency. Likewise, an
R
about 1.4. For ring frequencies greater than 20 Hz, the
R
factor is achieved. Note the RRNG is common to both
sections of the device.
18
18
RNG
RNG
RNG
are used to control or ramp the speed of the tran-
value of 34.8 k will raise the crest factor to
value should be lowered until the desirable crest
RNG
BAT
. The CF1 and CF2 capacitors should not
to 28.7 k provides a crest factor of 1.3
(continued)
RNG
and will be influenced slightly by the
(continued)
RNG
value of 22.6 k will
CF1 and CF2 must exhibit a stable capacitance value
over its voltage range to ensure a properly shaped
waveform. Do not use a ceramic capacitor for CF1 and
CF2; use a capacitor with a polyester, polypropylene,
polycarbonate, or polystyrene dielectric.
Notes:
Slew rate = 5.65 V/ms.
trise = tfall = 23 ms.
pwidth = 2 ms.
period = 50 ms.
Notes:
Slew rate = 10.83 V/ms.
trise = tfall = 12 ms.
pwidth = 13 ms.
period = 50 ms.
* Telcordia is a registered trademark of Telcordia Technologies, Inc.
Figure 18. Ringing Waveform Crest Factor = 1.6
Figure 19. Ringing Waveform Crest Factor = 1.2
–20
–40
–60
–80
–20
–40
–60
–80
80
60
40
20
80
60
40
20
0.00
0.00
0
0
0.02 0.06
0.02 0.06
0.04 0.08
0.04 0.08
TIME (s)
TIME (s)
0.10
0.10
0.12
0.12
0.14
0.14
0.16
0.16
Agere Systems Inc.
0.18
0.18
0.20
0.20
May 2001
12-3346a (F)
12-3347a (F)

Related parts for LUCL8576BP-D