NICRIO-9052 NI [National Instruments Corporation], NICRIO-9052 Datasheet - Page 2

no-image

NICRIO-9052

Manufacturer Part Number
NICRIO-9052
Description
High-Speed PCI Interfaces for CompactRIO
Manufacturer
NI [National Instruments Corporation]
Datasheet
High-Speed PCI Interface for CompactRIO
Specifications
StarFabric Communication
Interface .............................................. 4 LVDS transmit pairs,
Communication rates
1
Cabling requirements
Power Requirements
You must use a National Electric Code (NEC) Class 2 power source with
the cRIO-9052.
Recommended power supply.............. 48 W secondary,
Power consumption
Power supply
1
at the power connector.
Note: The cRIO-9052 powers up only at 9 V or higher, but after it is
powered up, it can run on as little as 6 V.
Physical Characteristics
If you need to clean the device, wipe it with a dry towel.
Screw-terminal wiring. ....................... 12 to 24 AWG copper conductor
Torque for screw terminals................. 0.5 to 0.6 N
Weight.................................................... Approx. 546 g (19.2 oz)
Safety
Safety Voltages
Connect only voltages that are within these limits.
V-to-C............................................................ 35 V max, Measurement Category I
Measurement Category I is for measurements performed on circuits not
directly connected to the electrical distribution system referred to as
MAINS voltage. MAINS is a hazardous live electrical supply system that
powers equipment. This category is for measurements of voltages from
specially protected secondary circuits. Such voltage measurements
include signal levels, special equipment, limited-energy parts of equipment,
circuits powered by regulated low-voltage sources, and electronics.
This rate varies depending on your host system specifications, such as processor, RAM, and so on.
This is the maximum amount of power that the entire system should consume
Theoretical maximum ..................... 133 MB/s
Typical
Cables ............................................. 2 shielded CAT5 Ethernet cables
Maximum difference between
Maximum cabling length................ 14 m (45.93 ft)
cRIO-9052 only................................ 1.5 W, max
cRIO-9052 supplying power to
8 CompactRIO modules .................. 17 W, max
On power up ................................... 9 to 35 V
After power up ............................... 6 to 35 V
the lengths of the two cables.... 2.54 cm (1 in.)
1
........................................... 50 MB/s
4 LVDS receive pairs
18 VDC to 24 VDC
wire with 10 mm (0.39 in.) of
insulation stripped from the end
(4.4 to 5.3 lb
1
m
in.)
Safety Standards
The cRIO-9052 is designed to meet the requirements of the following
safety standards for electrical equipment for measurement, control,and
laboratory use:
Note: For UL and other safety certifications, refer to the product label, or
visit ni.com/certification.
Environmental
The cRIO-9052 is intended for indoor use only. For outdoor use, mount
the CompactRIO system in a suitably rated enclosure.
Operating temperature
Note: To meet this operating temperature range, follow the guidelines in
the installation instructions for the CompactRIO system.
Storage temperature
Ingress protection ............................... IP 40
Operating humidity (IEC 60068-2-56)..... 10 to 90% RH, noncondensing
Storage humidity (IEC 60068-2-56)........ 5 to 95% RH, noncondensing
Maximum altitude............................... 2,000 m
Pollution degree (IEC 60664) .............. 2
Shock and Vibration
To meet these specifications, you must panel mount the
CompactRIOsystem and affix ferrules to the end of the terminal wires.
Operating vibration
Operating shock (IEC 60068-2-27) ...... 30 g, 11 ms half sine, 50 g,
Electromagnetic Compatibility
Emissions ............................................ EN 55011 Class A at 10 m FCC
Immunity.............................................. Industrial levels per EN
EMC/EMI............................................. CE, C-Tick, and FCC Part 15
Note: For EMC compliance, operate this device with shielded cabling.
CE Compliance
This product meets the essential requirements of applicable European
directives, as amended for CE marking, as follows:
Low-Voltage Directive (safety) ........... 73/23/EEC
Electromagnetic Compatibility
Note: Refer to the Declaration of Conformity (DoC) for this product for
any additional regulatory compliance information. To obtain the DoC for
this product, visit ni.com/certification.
EN 61010-1, IEC 61010-1
UL 61010-1
CAN/CSA-C22.2 No. 61010-1
(IEC 60068-2-1, IEC 60068-2-2) ...... -40 to 70 °C
(IEC 60068-2-1, IEC 60068-2-2) ...... -40 to 85 °C
Random (IEC 60068-2-64) ............... 5 g
Sinusoidal (IEC 60068-2-6) ............. 5 g, 10 to 500 Hz
Directive (EMC)............................... 89/336/EEC
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
3 ms half sine,
18 shocks at 6 orientations
Part 15A above 1 GHz
61326:1997 + A2:2001, Table A.1
(Class A) Compliant
rms
, 10 to 500 Hz
2