AM79514-1JC AMD [Advanced Micro Devices], AM79514-1JC Datasheet - Page 5

no-image

AM79514-1JC

Manufacturer Part Number
AM79514-1JC
Description
Subscriber Line Interface Circuit
Manufacturer
AMD [Advanced Micro Devices]
Datasheet
ABSOLUTE MAXIMUM RATINGS
Storage temperature ......................... –55°C to +150°C
V
V
V
Note: Rise time of V
less when Q
BGND with respect to AGND/DGND.. +1.0 V to –3.0 V
A(TIP) or B(RING) to BGND:
Current from A(TIP) or B(RING)
Voltage on RINGOUT ....... BGND to 70 V above Q
Voltage on TESTOUT ....... BGND to 70 V above Q
Current through relay drivers .............................60 mA
Voltage on ring-trip inputs DA and DB .......V
Current into ring-trip inputs
Peak current into regulator switch (L pin) ........150 mA
Switcher transient peak off voltage on L pin ......+1.0 V
C4–C1, E1, CHCLK,
Maximum power dissipation, (see note) ...... T
Note: Thermal limiting circuitry on chip will shut down the
circuit at a junction temperature of about 165°C. The device
should never be exposed to this temperature. Operation
above 145°C junction temperature may degrade device
reliability. See the SLIC Packaging Considerations for more
information.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent device failure. Functionality at or above
these limits is not implied. Exposure to Absolute Maximum
Ratings for extended periods may affect device reliability.
CC
EE
BAT
Continuous .................................... –70 V to +1.0 V
10 ms (f = 0.1 Hz) .......................... –70 V to +5.0 V
1 s (f = 0.1 Hz) .............................. –90 V to +10 V
250 ns (f = 0.1 Hz) ........................ –120 V to +15 V
to AGND/DGND ....................–0.4 V to V
In 32-pin PLCC package..............................1.74 W
with respect to AGND/DGND...... +0.4 V to –7.0 V
with respect to AGND/DGND ..... –0.4 V to +7.0 V
with respect to AGND/DGND ..... +0.4 V to –70 V
BAT
bypass = 0.33 F.
BAT
(dv/dt) must be limited to 27 V/ s or
CC
BAT
A
150 mA
+ 0.4 V
= 70°C
10 mA
to 0 V
SLIC Products
BAT
BAT
OPERATING RANGES
Commercial (C) Devices
Ambient temperature .............................0°C to +70°C*
V
V
V
AGND/DGND .......................................................... 0 V
BGND with respect to
Load resistance on VTX to ground .............. 10 k
Operating Ranges define those limits between which the
functionality of the device is guaranteed.
* Functionality of the device from 0 C to +70 C is guaranteed
by production testing. Performance from –40°C to +85°C is
guaranteed by characterization and periodic sampling of
production units.
CC
EE
BAT
AGND/DGND........................ –100 mV to +100 mV
.....................................................4.75 V to 5.25 V
.................................................–4.75 V to –5.25 V
......................................................–40 V to –63 V
min
5

Related parts for AM79514-1JC