HMC612LP4E HITTITE [Hittite Microwave Corporation], HMC612LP4E Datasheet

no-image

HMC612LP4E

Manufacturer Part Number
HMC612LP4E
Description
75 dB LOGARITHMIC DETECTOR / CONTROLLER, 50 Hz - 3000 MHz
Manufacturer
HITTITE [Hittite Microwave Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HMC612LP4E
Manufacturer:
HITTITE
Quantity:
5 000
Part Number:
HMC612LP4E
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
HMC612LP4ETR
Manufacturer:
ZCOMM
Quantity:
1 400
7 - 60
7
Typical Applications
The HMC612LP4(E) is ideal for IF and RF applica-
tions in:
• Cellular/PCS/3G
• WiMAX, WiBro, WLAN, Fixed Wireless & Radar
• Power Monitoring & Control Circuitry
• Receiver Signal Strength Indication (RSSI)
• Automatic Gain & Power Control
Functional Diagram
Electrical Specifi cations,
Input Frequency
±3 dB Dynamic Range
±3 dB Dynamic Range Center
±3 dB Dynamic Range Center
±1 dB Dynamic Range
Output Slope
Output Intercept
Output Intercept
Temperature
Sensitivity @ -43 dBV Input
Temperature
Sensitivity @ -30 dBm Input
[1] Detector mode measurements; LOGOUT (Pin 17) is shorted to VSET (Pin 18).
[2] Measured from T
Parameter
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
A
= -45C to T
[2]
[2]
0.00005 0.0001
A
Typ.
19.7
-110
-9.9
-45
= +85C, Vdd1, Vdd2 = 5V
75
68
-110.2
-44.5
-11.9
T
Typ.
19.7
75
67
A
v01.0108
= +25C
Order On-line at www.hittite.com
-110.6
0.001
DETECTOR / CONTROLLER, 50 Hz - 3000 MHz
-45.5
-11.3
Typ.
19.6
75
68
[1]
-110.6 -110.0
-11.3
0.01
Typ.
19.6
-45
75
67
-11.3
19.8
Typ.
-45
0.1
74
65
HMC612LP4
-94.5
-12.5
Typ.
19.7
-30
74
68
Features
Wide Input Bandwidth: 50 Hz to 3 GHz
Wide Dynamic Range: Up to 74 dB
High Accuracy: ±1 dB with 60 dB Range Up to 0.9 GHz
Supply Voltage: +2.7V to +5.5V
Excellent Stability over Temperature
Power-Down Mode
Compact 4x4mm Leadless SMT Package
General Description
The HMC612LP4(E) Logarithmic Detector/Controller is
ideal for converting input signals with frequencies in the
50 Hz to 3 GHz range, to a proportional DC voltage at
its output. The HMC612LP4(E) employs a successive
compression technology which delivers extremely high
dynamic range and conversion accuracy over a wide
input frequency range. As the input signal is increased,
successive amplifi ers move into saturation one by one
creating an accurate approximation of the logarithm
function. The output of a series of square law detectors
is summed, converted into voltage domain and buff-
ered to drive the LOGOUT output. For detection mode,
the LOGOUT pin is shorted to the VSET input and will
provide a nominal logarithmic slope of 19 mV/dB and an
intercept of -99 dBm. The HMC612LP4(E) can also be
used in the controller mode where an external voltage
is applied to the VSET pin, to create an AGC or APC
feedback loop.
1
-93.9
-12.2
Typ.
19.8
-30
66
10
74
-93.8
-11.7
19.8
Typ.
100
-30
74
66
-94.8
75 dB LOGARITHMIC
-11.2
Typ.
19.4
900
-31
72
64
1900
-92.5
-11.7
Typ.
19.4
-33
64
55
/
612LP4E
2500
-91.3
-12.1
Typ.
19.8
-34
60
52
3000
-86.4
-13.4
Typ.
20.8
-34
55
45
mdBm/°C
mdBV/°C
mV/dB
Units
dBm
dBm
MHz
dBV
dBV
dB
dB

Related parts for HMC612LP4E

HMC612LP4E Summary of contents

Page 1

Typical Applications The HMC612LP4(E) is ideal for IF and RF applica- tions in: • Cellular/PCS/3G • WiMAX, WiBro, WLAN, Fixed Wireless & Radar • Power Monitoring & Control Circuitry 7 • Receiver Signal Strength Indication (RSSI) • Automatic Gain & ...

Page 2

Electrical Specifi cations, (continued) Parameter LOGOUT Interface Output Voltage Range Output Rise Time/Fall Time @ -15 dBm VSET Interface Input Impedance Input Voltage Range Power Down (EN) Interface Voltage Range for Normal Mode Voltage Range for Powerdown Mode Threshold ...

Page 3

LOGOUT Voltage & Error vs. Input Signal, Fin = 1 kHz 2.6 ERR (+25c) 2.2 ERR (+85c) ERR (-45c) 1.8 1 0.6 0.2 -90 -80 -70 -60 -50 LOGOUT Voltage & Error vs. Input Power, Fin = 1 ...

Page 4

LOGOUT Voltage & Error vs. Input Power, Fin = 1900 MHz 2.6 ERR +25C 2.2 ERR +85C ERR -45C 1.8 1.4 1 Ideal 0.6 LOGOUT +25C LOGOUT +85C LOGOUT -45C 0.2 -70 -60 -50 -40 -30 -20 -10 INPUT ...

Page 5

LOGOUT Intercept vs. Supply Voltage, T -50 -60 1MHz 10MHz 100MHz -70 900MHz -80 7 -90 -100 -110 2.5 3 3.5 Vcc (Volts) Input Return Loss vs. Frequency, Vcc= 3. -10 -15 -20 -25 -30 - ...

Page 6

... Package Information Part Number Package Body Material HMC612LP4 Low Stress Injection Molded Plastic HMC612LP4E RoHS-compliant Low Stress Injection Molded Plastic [1] Max peak refl ow temperature of 235 °C [2] Max peak refl ow temperature of 260 °C [3] 4-Digit lot number XXXX For price, delivery, and to place orders, please contact Hittite Microwave Corporation: ...

Page 7

Pin Descriptions Pin Number Function 12, N/C 15 Vcc1, Vcc2 3, 4 INP, INN 13 CLPF 14 PWD For price, delivery, and to place orders, please contact Hittite Microwave Corporation: ...

Page 8

Pin Descriptions Pin Number Function VSET input in controller mode. Short this 16 VSET pin to LOGOUT for detector mode. Logarithmic output that converts the input power 17 LOGOUT level in detector mode. Short this pin ...

Page 9

... Capacitor, 0805 Pkg. R1, R2 6.8Ω Resistor, 0603 Pkg. R3, R4, R5 0Ω Resistor, 0603 Pkg. R6 49.9Ω Resistor, 0402 Pkg. HMC612LP4 / HMC612LP4E U1 Logarithmic Detector / Controller [2] PCB 118978 Evaluation PCB [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...

Page 10

... Application & Evaluation PCB Schematic Notes Note 1: The HMC612LP4 & HMC612LP4E evaluation boards are pre-assembled for single-ended input, and detector/RSSI mode. Note 2: For detector mode, connect high impedance volt meter to the LOGOUT port. VSET is shorted to LOGOUT by R3, as required for detector mode. ...

Related keywords