0850-0004 EnerSys, 0850-0004 Datasheet - Page 17

BATT CYCLON SLA 2V 8.0AH

0850-0004

Manufacturer Part Number
0850-0004
Description
BATT CYCLON SLA 2V 8.0AH
Manufacturer
EnerSys
Series
Cyclon®r
Datasheets

Specifications of 0850-0004

Voltage - Rated
2V
Capacity
8.0Ah
Size / Dimension
1.75" Dia x 3.94" H (44.5mm x 100.1mm)
Termination Style
Spade, .250" (6.3mm)
Rechargeability
Yes
Weight
1.1 lbs (498.95g)
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
842-1003
Another consideration is the potential failure of the charger. If
the charger malfunctions, causing higher-than-recommended
charge rates, substantial volumes of hydrogen and oxygen will
be vented from the cell. This mixture is explosive and should
not be allowed to accumulate. Therefore, despite its significant
advantages over other lead-acid batteries, the CYCLON
batteries SHOULD NEVER BE CHARGED IN A GAS-TIGHT
CONTAINER.
8.3 Shorting
CYCLON batteries have very low internal impedance and
thus are capable of delivering high currents if externally short
circuited. The resultant heat can cause severe burns and is a
Table 8-1
www.enersys.com
Figure A-1: Single Cell CC Graphs to 1.67 VPC
1000
4.5Ah (DT)
25Ah (BC)
100
0.1
2.5Ah (D)
10
Battery
12Ah (J)
5Ah (X)
8Ah (E)
1
0.01
12V
Appendix A
D
0.000052
0.00003
0.00005
0.00008
0.00025
0.1
2.27 VPC
0.0012
Hours to 1.67 VPC at 25°C/77°F
evolved per battery,
TD
Hydrogen gas
cc/sec.
X
1
0.00052
0.00012
2.45 VPC
0.0003
0.0005
0.0008
0.0025
E
10
J
0.00064
0.00066
0.0004
0.0010
0.0015
0.0032
Cu. ft/hr. of airflow to keep hydrogen accumulation below:
1%
BC
®
100
cells/
0.00032
0.00033
Table A-1: Amperes per Single Cell Data to 1.67 VPC
0.0002
0.0005
0.0008
0.0016
Run Time
2.27 VPC
2%
10 min.
15 min.
20 min.
30 min.
45 min.
2 min.
5 min.
10 hr.
20 hr.
1 hr.
2 hr.
3 hr.
4 hr.
5 hr.
8 hr.
potential fire hazard. Particular caution should be used when
the person working near the open terminals of cells or batteries
is wearing metal rings or watchbands.
Accidentally placing metal articles across the terminals could
result in severe skin burns. It is a good practice to remove all
metallic items such as watches, bracelets and personal jewelry
when working on or around battery terminals.
As a further precaution, when installing batteries or working on
them, insulating gloves should be worn and only insulated tools
should be used to prevent accidental short circuits.
0.00016
0.00017
0.0001
0.0003
0.0004
0.0008
24.6
14.3
2.75
0.80
0.60
0.48
0.30
0.26
0.14
8.9
5.9
5.3
3.8
1.9
1.2
D
4%
Tall D
34.9
22.8
14.9
10.8
0.83
0.55
0.42
0.23
9.1
6.6
4.7
3.6
2.0
1.4
1.0
0.00636
0.00661
Publication No: US-CYC-AM-007 - April 2008
0.0038
0.0102
0.0153
0.0318
1%
44.1
27.3
17.4
12.9
10.4
0.96
0.60
0.50
0.30
7.6
5.4
4.2
2.3
1.6
1.2
X
55.9
39.0
26.4
20.0
16.4
12.0
0.81
0.40
8.6
6.8
3.6
2.5
1.9
1.6
1.0
0.00318
0.00331
E
0.0019
0.0051
0.0076
0.0159
2.45VPC
2%
63.3
47.1
33.2
27.9
21.4
16.0
11.7
0.60
9.7
5.1
3.6
2.8
2.3
1.5
1.2
J
0.00159
0.00165
0.0010
0.0025
0.0038
0.0079
4%
164.7
113.6
76.7
60.0
47.8
35.2
25.4
20.0
10.9
7.6
5.8
4.9
3.1
2.6
1.4
BC
17

Related parts for 0850-0004