LF2005-S_06 LEM [LEM], LF2005-S_06 Datasheet

no-image

LF2005-S_06

Manufacturer Part Number
LF2005-S_06
Description
Current Transducer
Manufacturer
LEM [LEM]
Datasheet
Current Transducer LF 2005-S
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
I
R
I
K
V
I
V
X
I
I
t
di/dt
f
T
T
R
m
Notes :
LEM
PN
P
SN
C
O
OT
r
C
d
A
S
M
G
N
L
S
Electrical data
Accuracy - Dynamic performance data
General data
Primary nominal r.m.s. current
Primary current, measuring range @ ± 24 V
Measuring resistance
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
Overall accuracy @ I
Linearity error
Offset current @ I
Thermal drift of I
Response time
di/dt accurately followed
Frequency bandwidth (- 1 dB)
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ T
Mass
Standards
1)
2)
With a di/dt of 100 A/µs
A list of corresponding tests is available.
with ± 15 V
with ± 24 V
2)
1)
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
O
@ 90 % of I
P
= 0, T
PN
, T
A
16103
A
= 25°C
@ ± 2000 A
@ ± 2200 A
@ ± 2000 A
@ ± 3000 A
= 25°C
- 25°C .. + 70°C
PN
A
= 70°C
max
max
max
max
2000
0 .. ± 3000
R
400
1 : 5000
± 15 .. 24
33
6
± 0.3
< 0.1
< 1
> 50
DC .. 100
- 25 .. + 70
- 40 .. + 85
25
1.5
EN 50178
± 0.2 ± 0.4
0
0
5
5
Typ
M min
(@ ± 24 V) +
± 0.5
Max
R
29
11
8
5
M max
I
S
A/µs
kHz
mA
mA
mA
mA
kV
µs
°C
°C
k g
%
%
A
A
V
I
Features
Advantages
Applications
PN
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0.
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
=
2000 A
w w w .lem.com
060425/6
Page 1/2

Related parts for LF2005-S_06

LF2005-S_06 Summary of contents

Page 1

Current Transducer LF 2005-S For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). 16103 Electrical data I Primary nominal r.m.s. current PN I ...

Page 2

Dimensions LF 2005-S (in mm 0.0394 inch) Front view Top view Mechanical characteristics General tolerance ± 0.5 mm Fastening transducer 4 holes Flat or vertical position 4 screw M6 steel Fastening torque 5 4.05 Lb. ...