Datasheet
Table 86. Flash Status Register (FSTAT)
PS017610-0404
RESET
FIELD
ADDR
BITS
R/W
Flash Status Register
R
7
0
The Flash Status register indicates the current state of the Flash Controller. This register
can be read at any time. The Read-only Flash Status Register shares its Register File
address with the Write-only Flash Control Register.
Reserved
These bits are reserved and must be 0.
FSTAT—Flash Controller Status
000000 = Flash Controller locked.
000001 = First unlock command received.
000010 = Flash Controller unlocked (second unlock command received).
001xxx = Program operation in progress.
010xxx = Page erase operation in progress.
100xxx = Mass erase operation in progress.
Reserved
R
6
0
R
5
0
R
4
0
Z8F640x/Z8F480x/Z8F320x/Z8F240x/Z8F160x
FF8H
R
3
0
FSTAT
R
2
0
R
1
0
Z8 Encore!
Flash Memory
R
0
0
®