P89C660 Philips Semiconductors, P89C660 Datasheet - Page 47

no-image

P89C660

Manufacturer Part Number
P89C660
Description
80C51 8-bit Flash microcontroller family
Manufacturer
Philips Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P89C660HBA
Manufacturer:
PHI
Quantity:
5 030
Part Number:
P89C660HBA
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
P89C660HBA/00,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
P89C660HBBD
Manufacturer:
PHILIPS
Quantity:
586
Part Number:
P89C660HFA
Manufacturer:
NXP
Quantity:
1 832
Part Number:
P89C660HFA/00,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
When used for framing error detect, the UART looks for missing stop
Philips Semiconductors
Enhanced UART
In addition to the standard operation, the UART can perform framing
error detect by looking for missing stop bits, and automatic address
recognition. The UART also fully supports multiprocessor
communication as does the standard 80C51 UART.
bits in the communication. A missing bit will set the FE bit in the
S0CON register. The FE bit shares the S0CON.7 bit with SM0, and
the function of S0CON.7 is determined by PCON.6 (SMOD0) (see
Figure 32). If SMOD0 is set then S0CON.7 functions as FE.
S0CON.7 functions as SM0 when SMOD0 is cleared. When used as
FE, S0CON.7 can only be cleared by software (refer to Figure 33).
Automatic Address Recognition
Automatic Address Recognition is a feature which allows the UART
to recognize certain addresses in the serial bit stream by using
hardware to make the comparisons. This feature saves a great deal
of software overhead by eliminating the need for the software to
examine every serial address which passes by the serial port. This
feature is enabled by setting the SM2 bit in S0CON. In the 9-bit
UART modes (mode 2 and mode 3), the Receive Interrupt flag (RI)
will be automatically set when the received byte contains either the
“Given” address or the “Broadcast” address. The 9-bit mode
requires that the 9th information bit is a 1 to indicate that the
received information is an address and not data. Automatic address
recognition is shown in Figure 34.
The 8-bit mode is called Mode 1. In this mode, the RI flag will be set
if SM2 is enabled and the information received has a valid stop bit
following the 8 address bits, and the information is either a Given or
Broadcast address.
Mode 0 is the Shift Register mode and SM2 is ignored.
Using the Automatic Address Recognition feature allows a master to
selectively communicate with one or more slaves by invoking the
Given slave address or addresses. All of the slaves may be
contacted by using the Broadcast address. Two special Function
Registers are used to define the slave’s address, SADDR, and the
address mask, SADEN. SADEN is used to define which bits in the
SADDR are to be used and which bits are “don’t care”. The SADEN
mask can be logically ANDed with the SADDR to create the “Given”
address which the master will use for addressing each of the slaves.
Use of the Given address allows multiple slaves to be recognized
while excluding others. The following examples will help to show the
versatility of this scheme:
Slave 0
2002 Oct 28
80C51 8-bit Flash microcontroller family
16KB/32KB/64KB ISP/IAP Flash with 512B/1KB/2KB/8KB RAM
SADDR =
SADEN =
Given
=
1100 0000
1111 1101
1100 00X0
47
uniquely addressed by 1110 0110. Slave 1 requires that bit 1 = 0 and
cares”. This effectively disables the Automatic Addressing mode and
Slave 1
In the above example SADDR is the same and the SADEN data is
used to differentiate between the two slaves. Slave 0 requires a 0 in
bit 0 and it ignores bit 1. Slave 1 requires a 0 in bit 1 and bit 0 is
ignored. A unique address for Slave 0 would be 1100 0010 since
slave 1 requires a 0 in bit 1. A unique address for slave 1 would be
1100 0001 since a 1 in bit 0 will exclude slave 0. Both slaves can be
selected at the same time by an address which has bit 0 = 0 (for
slave 0) and bit 1 = 0 (for slave 1). Thus, both could be addressed
with 1100 0000.
In a more complex system the following could be used to select
slaves 1 and 2 while excluding slave 0:
Slave 0
Slave 1
Slave 2
In the above example the differentiation among the 3 slaves is in the
lower 3 address bits. Slave 0 requires that bit 0 = 0 and it can be
it can be uniquely addressed by 1110 and 0101. Slave 2 requires
that bit 2 = 0 and its unique address is 1110 0011. To select Slaves 0
and 1 and exclude Slave 2 use address 1110 0100, since it is
necessary to make bit 2 = 1 to exclude slave 2.
The Broadcast Address for each slave is created by taking the
logical OR of SADDR and SADEN. Zeros in this result are trended
as don’t-cares. In most cases, interpreting the don’t-cares as ones,
the broadcast address will be FF hexadecimal.
Upon reset, SADDR (SFR address 0A9H) and SADEN (SFR
address 0B9H) are leaded with 0s. This produces a given address
of all “don’t cares” as well as a Broadcast address of all “don’t
allows the microcontroller to use standard 80C51 type UART drivers
which do not make use of this feature.
P89C660/P89C662/P89C664/
SADDR =
SADEN =
Given
SADDR =
SADEN =
Given
SADDR =
SADEN =
Given
SADDR =
SADEN =
Given
=
=
=
=
1100 0000
1111 1110
1100 000X
1100 0000
1111 1001
1100 0XX0
1110 0000
1111 1010
1110 0X0X
1110 0000
1111 1100
1110 00XX
P89C668