ATMEGA48V ATMEL Corporation, ATMEGA48V Datasheet - Page 22

no-image

ATMEGA48V

Manufacturer Part Number
ATMEGA48V
Description
8-bit Microcontroller with 8K Bytes In-System Programmable Flash
Manufacturer
ATMEL Corporation
Datasheets

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATMEGA48V
Manufacturer:
ALTERA
0
Part Number:
ATMEGA48V
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATMEGA48V-10AI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA48V-10AJ
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA48V-10AU
Manufacturer:
ATM
Quantity:
10 000
Part Number:
ATMEGA48V-10AU
Manufacturer:
MOT
Quantity:
53
Part Number:
ATMEGA48V-10AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA48V-10AU
Manufacturer:
ATMEL
Quantity:
300
Part Number:
ATMEGA48V-10AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATMEGA48V-10MI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATMEGA48V-10MMU
Manufacturer:
ZILOG
Quantity:
1
Part Number:
ATMEGA48V-10PI
Manufacturer:
AGERE
Quantity:
85
Part Number:
ATMEGA48V-10U
Manufacturer:
CY
Quantity:
2
Part Number:
ATMEGA48V-12AI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
8. Errata
8.1
8.1.1
8.1.2
8.1.3
22
Errata ATmega48
ATmega48/88/168
Rev. D
Rev. C
Rev. B
The revision letter in this section refers to the revision of the ATmega48 device.
1. Interrupts may be lost when writing the timer registers in the asynchronous timer
1.
2. Interrupts may be lost when writing the timer registers in the asynchronous timer
1. Interrupts may be lost when writing the timer registers in the asynchronous timer
Interrupts may be lost when writing the timer registers in the asynchronous timer
Reading EEPROM when system clock frequency is below 900 kHz may not work
Interrupts may be lost when writing the timer registers in the asynchronous timer
Interrupts may be lost when writing the timer registers in the asynchronous timer
If one of the timer registers which is synchronized to the asynchronous timer2 clock is writ-
ten in the cycle before an overflow interrupt occurs, the interrupt may be lost.
Problem Fix/Workaround
Always check that the Timer2 Timer/Counter register, TCNT2, does not have the value 0xFF
before writing the Timer2 Control Register, TCCR2, or Output Compare Register, OCR2.
The only safe time to write to any of the Timer2 registers in asynchronous mode is in a com-
pare interrupt routine where the compare register is not 0xFF, or if the compare register is
0xFF, after a delay of at least one asynchronous clock cycle from the start of the interrupt.
Reading EEPROM when system clock frequency is below 900 kHz may not work
Reading Data from the EEPROM at system clock frequency below 900 kHz may result in
wrong data read.
Problem Fix/Workaround
Avoid using the EEPROM at clock frequency below 900 kHz.
If one of the timer registers which is synchronized to the asynchronous timer2 clock is writ-
ten in the cycle before an overflow interrupt occurs, the interrupt may be lost.
Problem Fix/Workaround
Always check that the Timer2 Timer/Counter register, TCNT2, does not have the value 0xFF
before writing the Timer2 Control Register, TCCR2, or Output Compare Register, OCR2.
The only safe time to write to any of the Timer2 registers in asynchronous mode is in a com-
pare interrupt routine where the compare register is not 0xFF, or if the compare register is
0xFF, after a delay of at least one asynchronous clock cycle from the start of the interrupt.
If one of the timer registers which is synchronized to the asynchronous timer2 clock is writ-
ten in the cycle before an overflow interrupt occurs, the interrupt may be lost.
2545LS–AVR–08/07

Related parts for ATMEGA48V