Description
Interval- and Wipe/ Wash Wiper Control IC
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
U642B-FP
Manufacturer:
DHA
Quantity:
20 000
Interval- and Wipe/ Wash Wiper Control IC
Description
As a convenience feature of the windshield wiper
intermittent and wipe/wash operation are implemented in
most of the automobiles. The U642B is the low-cost
solution for an accurate timing function control.
Wipe/wash mode has priority over interval mode. Interval
pause and afterwiping time can be set to fixed values by
Features
D Interval pause: 4 to 20 s
D Afterwiping time: 2 to 20 s
D Wiper motor’s park switch
D Wipe/wash mode priority
Block Diagram
Rev. A4, 10-Apr-01
GND
V S
1
8
V Ref
V Ref
Load-dump
comparator
comparator
Interval
OUT
Figure 1. Block diagram
7
A
INT
2
B
using resistors in a broad time range. Added value can be
provided with an individual, continuous adjustment of the
interval pause by a potentiometer which may be built into
the stalk. For proper operation it is mandatory to feed the
signal of the wiper motor‘s park switch into U642B.
D One external capacitor, determines all time sequences
D Relay driver with Z-diode
D Interference protection according to VDE 0839 or
D Load-dump protected
PARK
Logic
C
ISO/TR 7637/1
6
Park switch
V Ref
comparator
C
t
D
3
WASH
E
5
comparator
V Ref
F
Input
Wipe / wash
comparator
R
t
4
94 8950
U642B
1 (7)

Related parts for U642B-FP

U642B-FP Summary of contents

Page 1

... Description As a convenience feature of the windshield wiper intermittent and wipe/wash operation are implemented in most of the automobiles. The U642B is the low-cost solution for an accurate timing function control. Wipe/wash mode has priority over interval mode. Interval pause and afterwiping time can be set to fixed values by ...

Page 2

... V. The wipe/ wash function is not interrupted when interval switch S is activated. Interval function begins after the 2 WIWA function is over. Remarks OUT 2 7 U642B C 6 PARK 3 t WASH 7691 Figure 2. Pinning . Afterwards the Time ...

Page 3

... Figure 3. Application circuit with interval and wipe/wash operation Rev. A4, 10-Apr- U642B 2 130 kW time Interval switch U642B WIWA 8951 Water pump 3 (7) ...

Page 4

... U642B Absolute Maximum Ratings Parameters Supply voltage Supply current 200 ms Relay control output current (DC 200 ms Pulse current (control inputs) Park switch, S Wipe/Wash switch, S Interval switch, S Power dissipation amb Storage temperature range Ambient temperature range Thermal Resistance ...

Page 5

... Figure 6. Interval pause = time 130 kW time 4 = 300 kW time 100 –40 14007 Figure 7. Afterwiping time = U642B Min. Typ. Max. Unit –1.4/–5.4 –0.8 7.6 3.6 4 4.4 10.8 12 13.2 100 ms 4.75 5.25 5. Interval resistor ( ...

Page 6

... U642B Package Information Package DIP8 Dimensions Package SO8 Dimensions in mm 0.4 1. (7) 9.8 9.5 1.64 1.44 4.8 max 6.4 max 3.3 0.5 min 0.36 max 0.58 2.54 0.48 7.62 5 technical drawings according to DIN specifications 4 5.2 4.8 5.00 4.85 3.7 1.4 0.25 3.8 0.10 6.15 3.81 5.85 5 technical drawings according to DIN specifications 4 7.77 7.47 9.8 8.2 13021 0.2 13034 Rev. A4, 10-Apr-01 ...

Page 7

... Data sheets can also be retrieved from the Internet: Atmel Germany GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany Telephone: 49 (0)7131 67 2594, Fax number: 49 (0)7131 67 2423 Rev. A4, 10-Apr-01 U642B http://www.atmel–wm.com 7 (7) ...

Related keywords