... The AT27C040 chip is a low-power, high-performance, 4,194,304-bit one-time pro- grammable read only memory (OTP EPROM) organized as 512K by 8 bits. The AT27C040 requires only one 5V power supply in normal read mode operation. Any byte can be accessed in less than 70 ns, eliminating the need for speed reducing WAIT states on high-performance microprocessor systems ...
Page 2
... The AT27C040 is available in a choice of industry standard JEDEC-approved one-time programmable (OTP) plastic PDIP, PLCC, SOIC (SOP), and TSOP packages. The device features two-line control (CE, OE) to eliminate bus contention in high-speed systems. Atmel's AT27C040 has additional features to ensure high quality and efficient production use. The Rapid ming Algorithm reduces the time required to program the part and guarantees reliable programming ...
Page 3
Block Diagram Operating Modes Mode/Pin Read Output Disable Standby (2) Rapid Program PGM Verify PGM Inhibit (4) Product Identification Notes can Refer to Programming Characteristics 12.0 0.5V. ...
Page 4
... -12 -15 0°C - 70°C 0°C - 70°C -40°C - 85°C -40°C - 85°C 5V 10% 5V 10% Min Max 100 1 30 -0.6 0 2.0 0.5 0.4 2 AT27C040 -12 -15 Max Min Max Min Max 90 120 150 90 120 150 Units and ...
Page 5
AC Waveforms for Read Operation Notes: 1. Tiiming measurement references are 0.8V and 2.0V. Input AC drive levels are 0.45V and 2.4V, unless otherwise specified may be delayed may be delayed up to ...
Page 6
... Programming Waveforms Notes: 1. The Input Timing Reference is 0.8V for and t are characteristics of the device but must be accommodated by the programmer. OE DFP 3. When programming the AT27C040 a 0.1 F capacitor is required across V sients. DC Programming Characteristics ± 5° 6.5 ± 0.25V Symbol Parameter I Input Load Current ...
Page 7
AC Programming Characteristics 5° 6.5 0.25V Symbol Parameter t Address Setup Time Setup Time OES t Data Setup Time DS t Address Hold Time AH t Data Hold Time ...
Page 8
... CE pulse without verification. Then a verifica- tion/reprogramming loop is executed for each address. In the event a byte fails to pass verification succes- sive 100 s pulses are applied with a verification after each AT27C040 8 pulse. If the byte fails to verify after 10 pulses have been is applied, the part is considered failed. After the byte verifies ...
Page 9
... AT27C040-70JI AT27C040-70PI AT27C040-70RI AT27C040-70TI 0.1 AT27C040-90JC AT27C040-90PC AT27C040-90RC AT27C040-90TC 0.1 AT27C040-90JI AT27C040-90PI AT27C040-90RI AT27C040-90TI 0.1 AT27C040-12JC AT27C040-12PC AT27C040-12RC AT27C040-12TC 0.1 AT27C040-12JI AT27C040-12PI AT27C040-12RI AT27C040-12TI 0.1 AT27C040-15JC AT27C040-15PC AT27C040-15RC AT27C040-15TC 0.1 AT27C040-15JI AT27C040-15PI AT27C040-15RI AT27C040-15TI Package Type Package Operation Range 32J Commercial 32P6 ( 32R 32T 32J ...