Page 1
... Both parts feature a 44V maximum breakdown voltage rat- ing that allows 30V peak-to-peak switch-off blocking capacity. The DG308A/DG309 can be used with split sup- plies (±5V to ±20V single positive supply (+5V to +30V), while retaining CMOS-logic-compatible inputs. ...
Page 2
... Plastic DIP (derate 10.53mW/°C above +70°C)............842mW Narrow SO (derate 8.70mW/°C above +70°C) .............696mW CERDIP (derate 10.00mW/°C above +70°C) ................800mW Operating Temperature Ranges DG308AC_/DG309C_ .........................................0°C to +70°C DG308AD_/DG309D_ ......................................-40°C to +85°C DG308AAK/DG309AK ...................................-55°C to +125°C Storage Temperature Range .............................-65°C to +150°C Lead Temperature (soldering, 10sec) .............................+300° ...
Page 3
... Capacitance f = 140kHz, V Drain-Off (DG308A D(OFF) Capacitance f = 140kHz, V Channel- (DG308A D(ON) IN Capacitance S(ON) S Note 1: All leads are soldered or welded to the PC board. Note 2: The algebraic convention where the most negative value is a minimum and the most positive value a maximum is used in this data sheet ...
Page 4
... Information The DG308A/DG309 switch positive analog signals while using a single positive supply, allowing use in applica- tions where only one supply is available. The disadvan- tages of using a single supply are slower switching speed and increased r Current and Voltage vs. Temperature graph shows the typical curve for a single-supply design ...