ADUM3223 AD [Analog Devices], ADUM3223 Datasheet - Page 6

no-image

ADUM3223

Manufacturer Part Number
ADUM3223
Description
Isolated Precision Half-Bridge Driver
Manufacturer
AD [Analog Devices]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM3223ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADUM3223ARZ
Quantity:
10 000
Part Number:
ADUM3223BRZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
ADUM3223BRZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUM3223CRZ
Quantity:
8 000
ADuM3223/ADuM4223
REGULATORY INFORMATION
The
Table 6.
UL
Recognized under UL 1577
Single/Protection 3000 V rms
File E214100
1
2
The
Table 7.
UL
Recognized under UL 1577
Single/Protection 5000 V rms
File E214100
1
2
In accordance with UL 1577, each ADuM3223 is proof tested by applying an insulation test voltage ≥ 3600 V rms for 1 second (current leakage detection limit = 6 µA).
In accordance with DIN V VDE V 0884-10, each ADuM3223 is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection
limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval.
In accordance with UL 1577, each ADuM4223 is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 µA).
In accordance with DIN V VDE V 0884-10, each ADuM4223 is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 second (partial discharge detection
limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval.
Component Recognition
Program
Isolation Voltage
Component Recognition
Program
Isolation Voltage
ADuM3223
ADuM4223
1
1
approval is pending by the organizations listed in Table 6.
approval is pending by the organizations listed in Table 7.
CSA
Approved under CSA Component Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-07 and IEC 60950-1,
400 V rms (565 V peak) maximum working voltage
Basic insulation per CSA 60950-1-07 and IEC 60950-1,
800 V rms (1131 V peak) maximum working voltage
File 205078
CSA
Approved under CSA Component Acceptance Notice #5A
Basic insulation per CSA 60950-1-07 and IEC 60950-1,
400 V rms (565 V peak) maximum working voltage
File 205078
Rev. 0| Page 6 of 20
VDE
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
Reinforced insulation, 849 V peak
File 2471900-4880-0001
VDE
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
Reinforced insulation, 560 V peak
File 2471900-4880-0001
2
2
Data Sheet

Related parts for ADUM3223