SP304 SIPEX [Sipex Corporation], SP304 Datasheet

no-image

SP304

Manufacturer Part Number
SP304
Description
RS-232/RS-422 Line Drivers/Receivers
Manufacturer
SIPEX [Sipex Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SP304N
Quantity:
6 228
DESCRIPTION…
The SP304 is an enhanced-performance version of the Sipex SP302 RS-232 and RS-422
protocol line drivers and receivers. It is pin-for-pin compatible with the SP302, and in any
configuration, fully meets the requirements of the EIA RS-232D and RS-422 data communication
standards. A loopback test mode is provided.The SP304 is available in 24-pin single width plastic
DIP, and 28-pin SOIC packages for commercial and industrial temperature range operation.
SIGNAL PROCESSING EXCELLENCE
SIGNAL PROCESSING EXCELLENCE
RS-232 and RS-422 on One Chip
Multiple Drivers and Receivers
Software-selectable Modes
Loopback for Self-Testing
Short-circuit Protected
Single-width 24-pin DIP and 28–pin
SOIC Packages
Corporation
Corporation
V
GND
V
V
DD
CC
EE
SELECT
A
RS-232/RS-422 Line Drivers/Receivers
B
LOOP–
BACK
TOB
TIB
1
1
TOB
TIB
2
2
TOA
TIA
1
TOA
1
2
ROB
RIB
1
1
RIB
ROB
2
2
RIA
ROA
1
RIA
1
SP304
2
SP304
77

Related parts for SP304

SP304 Summary of contents

Page 1

... It is pin-for-pin compatible with the SP302, and in any configuration, fully meets the requirements of the EIA RS-232D and RS-422 data communication standards. A loopback test mode is provided.The SP304 is available in 24-pin single width plastic DIP, and 28-pin SOIC packages for commercial and industrial temperature range operation. ...

Page 2

SPECIFICATIONS ( and nominal supply voltages unless otherwise noted) MIN A MAX PARAMETER MIN. RS-232 DRIVER TTL Input Level 2.0 IH High Level Output +5.0 Low Level Output Short Circuit Current Loopback Output Voltage Slew ...

Page 3

... This is an absolute maximum rating; normal operating levels are V 5. Outputs unloaded; Inputs tied to GND; T Typical SP304 current drains under full load are: 18mA (+12V), 10mA (-12V) and 7mA (+5V) in RS-232 mode only; 5mA (+12V), 7mA (-12V) and 56mA (+5V) in RS-422 mode only; ...

Page 4

... USING THE SP304 POWER SUPPLIES The SP304 requires 12V and +5V for full RS-232 and RS-422 operation. The 12V sup- plies set up the RS-232 9V voltage swings, and the +5V is used for the internal logic that for- mats the communications mode and controls the loopback function ...

Page 5

... EE device, the impedance from a transmitter output to ground must be greater than 300 . This can be easily achieved as shown in Figure 1a, where an external transistor is used as a switch to isolate an SP304 from ground in the power off V CC condition. With V switch is on, connecting ground (GND) for the device to the circuit ground power-off ...

Page 6

... RS-232 signal to an input that is configured for RS-422. 82 load. Figure 2 shows a typical circuit for the SP304. In this case the SP304 is shown configured for one (1) duplex RS-422 and two (2) duplex RS-232 communication paths. CONFIGURING THE SP304 ...

Page 7

... FIGURE 3: SP304 CONTROL LOGIC CONFIGURATION SELECTION LOGIC VALUE SELECT A: 0 SELECT B: 0 RIA ROA NON– 2 LOOPBACK RIA ROA ( TOA TIA 1 1 TOA TIA 2 2 RIB ROB 2 RIB ROB 1 TOB TIB 1 1 TOB TIB 2 2 LOOPBACK RIA ROA 2 (LB=0) RIA ROA ...

Page 8

... FIGURE 4: SP304 CONFIGURATIONS Four-Channel Duplex RS-232 Four independent channels of RS-232 line driver and four channels of RS-232 receiver. TIA TOA 1 1 TIA TOA 2 2 TIB TOB 1 1 TIB TOB 2 2 RS-232 LINE DRIVERS RS-232 RECEIVERS RIA 1 ROA 1 RIA 2 ROA 2 RIB 1 ROB 1 RIB ...

Page 9

... FIGURE 5: SP304 CONFIGURATIONS Two-Channel Duplex RS-232 & One-Channel Duplex RS-422 Opposite Drivers Two RS-232 line drivers and receivers, and a single RS-422 line driver and receiver. At first glance, this is the same configuration as that in Figure 4. Note however that functions are acti- vated on the opposite channels. ...

Page 10

... LOOPBACK The SP304 has a function called loopback, which is essentially a chip self-test. However, by connecting system test loops with the inputs and outputs of the SP304, a system-level diagnostic can be run on power- command. The test loops can be SP304 CONFIGURATIONS IN LOOPBACK MODE Two -Channel Full Duplex RS-232 ...

Page 11

... V to ground. Receiver EE outputs are left active for signal verification. SP304 CONFIGURATIONS IN LOOPBACK MODE One-Channel Full Duplex RS-232 & One-Channel Full Duplex RS-422 Opposite Drivers TIB TOB ...

Page 12

... Max # of Duplex Channels Model RS-232 RS-422 SP304CS .................. 4 ...................... 2 .................................... 0˚C to 70˚C ........................ 24-pin Single-Width Plastic DIP SP304CT .................. 4 ...................... 2 .................................... 0˚C to 70˚C ....................................................... 28-pin SOIC SP304ES .................. 4 ...................... 2 .................................. -40˚C to 85˚C ....................... 24-pin Single-Width Plastic DIP SP304ET .................. 4 ...................... 2 .................................. -40˚C to 85˚C ...................................................... 28-pin SOIC 88 ORDERING INFORMATION Temperature Package ...

Related keywords