SP3222E SIPEX [Sipex Corporation], SP3222E Datasheet - Page 13

no-image

SP3222E

Manufacturer Part Number
SP3222E
Description
True +3.0V to +5.5V RS-232 Transceivers
Manufacturer
SIPEX [Sipex Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SP3222EBCA-L
Manufacturer:
Exar
Quantity:
991
Company:
Part Number:
SP3222EBCA-L/TR
Quantity:
12 000
Part Number:
SP3222EBCY
Manufacturer:
SIPEX
Quantity:
20 000
Part Number:
SP3222EBET
Manufacturer:
SIPEX
Quantity:
3
Part Number:
SP3222EBEY
Manufacturer:
SIPEX
Quantity:
20 000
Part Number:
SP3222EBEY-L
Manufacturer:
SIPEX
Quantity:
529
Part Number:
SP3222EBEY-L/TR
Manufacturer:
SIPEX
Quantity:
3 500
Part Number:
SP3222EBEY-L/TR
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Part Number:
SP3222EC
Manufacturer:
SIPEX
Quantity:
20 000
Part Number:
SP3222ECA
Manufacturer:
SIPEX
Quantity:
20 000
Part Number:
SP3222ECA-L/TR
Manufacturer:
ST
Quantity:
12 000
Part Number:
SP3222ECY-L
Quantity:
296
Figure 17. ESD Test Circuit for Human Body Model
The Contact Discharge Method applies the ESD
current directly to the EUT. This method was
devised to reduce the unpredictability of the
ESD arc. The discharge current rise time is
constant since the energy is directly transferred
without the air-gap arc. In situations such as
hand held systems, the ESD charge can be
directly discharged to the equipment from a
person already holding the equipment. The
current is transferred on to the keypad or the
serial port of the equipment directly and then
travels through the PCB and finally to the IC.
Rev. 07/01/03
Figure 18. ESD Test Circuit for IEC1000-4-2
DC Power
Source
DC Power
Source
R
R
C
C
R
R
C
C
SW1
SW1
SP3222/3232E True +3.0 to +5.0V RS-232 Transceivers
SW1
SW1
C
C
13
S
S
The circuit models in Figures 17 and 18
represent the typical ESD testing circuits used
for all three methods. The C
with the DC power supply when the first
switch (SW1) is on. Now that the capacitor is
charged, the second switch (SW2) is on while
SW1 switches off. The voltage stored in the
capacitor is then applied through R
limiting resistor, onto the device under test
(DUT). In ESD tests, the SW2 switch is pulsed
so that the device under test receives a duration
of voltage.
R S and R V add up to 330Ω for IEC1000-4-2.
R S and R V add up to 330Ω for IEC1000-4-2.
C
C
R
S
R
S
S
S
Contact-Discharge Module
Contact-Discharge Module
R
R
S
S
R
R
V
V
SW2
SW2
SW2
SW2
© Copyright 2003 Sipex Corporation
S
is initially charged
Device
Under
Test
S
, the current
Device
Under
Test

Related parts for SP3222E