SP206 SIPEX [Sipex Corporation], SP206 Datasheet - Page 8

no-image

SP206

Manufacturer Part Number
SP206
Description
+5V High-Speed RS-232 Transceivers with 0.1uF Capacitors
Manufacturer
SIPEX [Sipex Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SP206BCA-L/TR
Manufacturer:
SIPEX
Quantity:
12 492
Part Number:
SP206BCT-L/TR
Manufacturer:
PAN
Quantity:
6 249
Part Number:
SP206BET-L/TR
Manufacturer:
SIPEX
Quantity:
9 828
Part Number:
SP206CA
Manufacturer:
SIPEX
Quantity:
20 000
Part Number:
SP206CA-L
Manufacturer:
Exar
Quantity:
135
Part Number:
SP206CA-L
Manufacturer:
Lattice
Quantity:
335
Part Number:
SP206CA-L
Manufacturer:
SIPEX
Quantity:
20 000
Part Number:
SP206CP
Manufacturer:
SIPEX
Quantity:
20 000
Part Number:
SP206CT
Manufacturer:
SIPEX
Quantity:
20 000
Company:
Part Number:
SP206CT-L/TR
Quantity:
3 670
Part Number:
SP206EA
Manufacturer:
SIPEX
Quantity:
20 000
Company:
Part Number:
SP206ET-L
Quantity:
1 185
SHUTDOWN MODE
The SP200, SP205, SP205B, SP206, SP206B,
SP207B, SP211, SP211B and SP213 all feature
a control input which will disable the device and
reduce the power supply current to less than
10µA, making the parts ideal for battery–pow-
ered systems. In the “shutdown” mode the re-
ceivers and transmitters will both be tri–stated.
The V
to V
ground. Products with the WakeUp function can
enable or disable the receivers during shutdown.
For complete shutdown to occur and the 10µA
power drain to be realized, the following condi-
tions must be met:
SP200, SP205/B, SP206/B, SP207B and SP211/B:
Table 2. Wake–Up Truth Table
REV: A DATE:12/03/2003
Figure 5. Charge Pump — Phase 4
SD
0
0
1
1
• +5V must be applied to the SD pin
• ENABLE must be either 0V, +5.0V or not
• the transmitter inputs must be either +5.0V
• V
• Receiver inputs must be >0V and <+5V
CC
connected
or not connected
+
, and the V
CC
output of the charge pump will discharge
EN
0
1
0
1
must be +5V
SP213 Only
SD
1
1
0
0
EN
1
0
1
0
output will discharge to
C
1
+
Up/Down
V
Power
Down
Down
CC
Up
Up
= +5V
C
Receiver
Outputs
Tri–state
Tri–state
2
Enable
Enable
+10V
+5V High-Speed RS232 Transceivers
+
8
+
C
C
4
ENABLE
The SP205/B, SP206/B, SP207/B, SP211 and
SP213 all feature an enable input, which allows
the receiver outputs to be either tri–stated or
enabled. This can be especially useful when the
receiver is tied directly to a microprocessor data
bus. For the SP205/B, SP206/B, SP207/B and
SP211, enable is active low; that is, 0V applied
to the ENABLE pin will enable the receiver
outputs. For the SP213, enable is active high;
that is, +5V applied to the ENABLE pin will
enable the receiver outputs.
WAKEUP FUNCTION
The SP205B, SP206B, SP207B, SP211B and
SP213 have a wake–up feature that keeps two or
more receivers in an enabled state when the
device is in the shutdown mode. The SP213 has
two receivers active (R
SP205B, SP207B and SP211B have all receiv-
ers active during shutdown. With only the re-
ceivers active during shutdown, the devices
draw 5–10µA of supply current.
3
+
SP213:
V
V
• 0V must be applied to the SD pin
• ENABLE must be either 0V, +5.0V or not
• the transmitter inputs must be either +5.0V
• V
• Receiver inputs must be >0V and <+5V
DD
SS
connected
or not connected
Storage Capacitor
CC
Storage Capacitor
must be +5V
© Copyright 2000 Sipex Corporation
4
and R
5
), while the

Related parts for SP206