PC900 SHARP [Sharp Electrionic Components], PC900 Datasheet - Page 11

no-image

PC900

Manufacturer Part Number
PC900
Description
DEVICE SPECIFICATION FOR PHOTOCOUPLER
Manufacturer
SHARP [Sharp Electrionic Components]
Datasheets

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PC900
Manufacturer:
SHARP
Quantity:
1 500
Part Number:
PC900
Manufacturer:
SHARP
Quantity:
20 000
Part Number:
PC900501DH1
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Company:
Part Number:
PC900719
Quantity:
184
Part Number:
PC900790GAGR2
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
PC900V
Quantity:
4 220
Part Number:
PC900V
Manufacturer:
SHARP
Quantity:
8 000
Part Number:
PC900V
Manufacturer:
SHARP
Quantity:
20 000
Part Number:
PC900V0NIPXF
Manufacturer:
FSC
Quantity:
15 900
Part Number:
PC900V0NIZXF
Manufacturer:
Sharp Microelectronics
Quantity:
135
Part Number:
PC900V0NIZXF
Manufacturer:
WINBOND
Quantity:
607
Part Number:
PC900V0NSZX6
Manufacturer:
SHARP
Quantity:
20 000
Part Number:
PC900VONSZXF
Manufacturer:
SHARP
Quantity:
1 000
SHARP CORPORRTION
2. Please use the same as normal integration circuit about static
3. In order to stabilize power supply line, we recommend to connect
4. The LED used in the Photocoupler generally decreases the light emission power
1. For cleaning
(31 Applicable
(1) Solvent cleaning : Solvent temperature 45°C or less
(21 Ultrasonic cleaning : The affect to device by ultrasonic cleaning is different
by operation.
the decreases of the light emission power of the LED. (50%/5yearsl
Please decide the input current which become 2 times of MAX. I,.
electricity
a by-pass capacitor of 0.0 1 p F or more between Vcc and GND near the device.
Please refrain form using Chloro Fluoro Carbon type solvent to clean
devise as much as possible since it is internationally
the ozonosphere.
to contirm that it does not attack package resin.
in order that this device is OPIC photocopier.
solvent : Ethyl alcohol, Methyl alcohol
In case of long operation time, please design the circuit with considering
Immersion for 3 mln or less
Precautions for Photocouplers
Freon TE . TF, Diflon-solvent
output, cleaning time, PWB size or device mounting
condition etc. Please test it in actual using condition
and confirm that doesn’t occur any defect before starting
the ultrasonic cleaning.
by cleaning bath size, ultrasonic power
Before you use alternative solvent you are requested
S3-E
restricted to protect
PCSOOV
Attach
sheet- 1- 1

Related parts for PC900