VRE114C ETC [List of Unclassifed Manufacturers], VRE114C Datasheet

no-image

VRE114C

Manufacturer Part Number
VRE114C
Description
Precision Reference Supplies
Manufacturer
ETC [List of Unclassifed Manufacturers]
Datasheet
DESCRIPTION
VRE114 Series Precision Voltage References
provide ultrastable +1.500V (VRE114), -1.500V
(VRE115) and ±1.500V (VRE116) outputs with
±150
coefficient as low as 0.8 ppm/°C over the full
military temperature range. This improvement in
accuracy
proprietary
technique developed by Thaler Corporation.
Significant improvements have been made in
other performance parameters as well, including
initial accuracy, warm-up drift, line regulation, and
long-term stability, making the VRE114 series the
most
available.
VRE114/115/116 devices are available in two
operating temperature ranges, -25°C to +85°C
and -55°C to +125°C, and two performance
grades. All devices are packaged in 14-pin hermetic ceramic packages for maximum long-term stability. "M"
versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make these references ideal for precision applications such as A/D
and D/A converters, high-accuracy test and measurement instrumentation, and transducer excitation.
• VERY HIGH ACCURACY: 1.500 V OUTPUT ±150 µV
• EXTREMELY LOW DRIFT: 0.8 ppm/°C 55°C to +125°C
• LOW WARM-UP DRIFT: 1 ppm Typ.
• EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
• EXCELLENT LINE REGULATION: 3 ppm/V Typ.
• HERMETIC 14-PIN CERAMIC DIP
• MILITARY PROCESSING OPTION
FEATURES
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
µV
accurate
is
initial
multipoint
made
and
accuracy
possible
stable
laser
VRE114/115/116
Precision
Reference Supplies
and
1.5V
by
compensation
temperature
a
reference
unique,
VRE114C
VRE114CA
VRE114M
VRE114MA
VRE115C
VRE115CA
VRE115M
VRE115MA
VRE116C
VRE116CA
VRE116M
VRE116MA
Type
APPLICATIONS
• PRECISION A/D and D/A CONVERTERS
• TRANSDUCER EXCITATION
• ACCURATE COMPARATOR THRESHOLD
• HIGH RESOLUTION SERVO SYSTEMS
• DIGITAL VOLTMETERS
• HIGH PRECISION TEST and
REFERENCE
MEASUREMENT INSTRUMENTS
Output
+1.5V
+1.5V
+1.5V
+1.5V
-1.5V
-1.5V
-1.5V
-1.5V
±1.5V
±1.5V
±1.5V
±1.5V
SELECTION GUIDE
Operating Range
-25°C to +85°C
-25°C to +85°C
-55°C to +125°C
-55°C to +125°C
-25°C to +85°C
-25°C to +85°C
-55°C to +125°C
-55°C to +125°C
-25°C to +85°C
-25°C to +85°C
-55°C to +125°C
-55°C to +125°C
Temperature
VRE114DS REV. C NOV 2000
Max. Volt
Deviation
240 µV
240 µV
120 µV
240 µV
150 µV
120 µV
150 µV
150 µV
120 µV
75 µV
75 µV
75 µV

Related parts for VRE114C

VRE114C Summary of contents

Page 1

... APPLICATIONS • PRECISION A/D and D/A CONVERTERS • TRANSDUCER EXCITATION • ACCURATE COMPARATOR THRESHOLD REFERENCE • HIGH RESOLUTION SERVO SYSTEMS • DIGITAL VOLTMETERS • HIGH PRECISION TEST and MEASUREMENT INSTRUMENTS Type temperature VRE114C VRE114CA by a unique, VRE114M compensation VRE114MA VRE115C VRE115CA VRE115M VRE115MA 1.5V ...

Page 2

SPECIFICATIONS ELECTRICAL Vps =±15V 25° 10k unless otherwise noted. MODEL PARAMETERS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX ABSOLUTE MAXIMUM RATINGS Power Supply ±13.5 Operating Temperature -25 Storage Temperature -65 Short ...

Page 3

TYPICAL PERFORMANCE CURVES V V vs. TEMPERATURE OUT OUT Temperature C o VRE114/115/116CA VRE114/115/116C QUIESCENT CURRENT VS. TEMP o Temperature C QUIESCENT CURRENT VS. TEMP o Temperature C QUIESCENT CURRENT VS. TEMP o Temperature C V vs. TEMPERATURE vs. TEMPERATURE ...

Page 4

DISCUSSION OF PERFORMANCE THEORY OF OPERATION The following discussion refers to the schematic below. A FET current source is used to bias a 6.3V zener diode. The zener voltage is divided by the resistor network R1 and R2. This voltage ...

Page 5

FIGURE 1 1. Optional Fine Adjust for approximately ±5mV. VRE115 trim pot center tap connects to -15V. TOP VIEW VRE114 -PS (VRE115) NC REF. GND GND 14-PIN HYBRID PACKAGE EXTERNAL CONNECTIONS PIN CONFIGURATION FINE ADJ. +1.5V (-1.5V) ...