INA200A BURR-BROWN [Burr-Brown Corporation], INA200A Datasheet - Page 4

no-image

INA200A

Manufacturer Part Number
INA200A
Description
High-Side Measurement Current-Shunt Monitor with Comparator and Reference
Manufacturer
BURR-BROWN [Burr-Brown Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
INA200AIDGKR
Manufacturer:
TI
Quantity:
357
Part Number:
INA200AIDGKR
Manufacturer:
TI
Quantity:
1 121
Part Number:
INA200AIDGKR
Manufacturer:
TI
Quantity:
1 000
Part Number:
INA200AIDGKR
Manufacturer:
TI
Quantity:
1 121
Part Number:
INA200AIDGKR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
INA200AIDGKR
0
Part Number:
INA200AIDGKT
Manufacturer:
TI
Quantity:
2
Part Number:
INA200AIDGKT
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
INA200AIDR
Manufacturer:
TI
Quantity:
357
Part Number:
INA200AIDR
Manufacturer:
TI
Quantity:
751
Part Number:
INA200AIDR
Manufacturer:
TI
Quantity:
751
Part Number:
INA200AIDR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
INA200AQDGKRQ1
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
INA200AQDGKRQ1
0
INA200
INA201
INA202
SBOS374 − NOVEMBER 2006
4
ELECTRICAL CHARACTERISTICS: COMPARATOR
Boldface limits apply over the specified temperature range: T
At T
noted.
(5) The comparator response time specified is the interval between the input step function and the instant when the output crosses 1.4V.
(6) The RESET input has an internal 2MΩ (typical) pull-down. Leaving RESET open results in a LOW state, with transparent comparator operation.
OFFSET VOLTAGE
Threshold
Hysteresis
INPUT BIAS CURRENT
CMP
INPUT VOLTAGE RANGE
CMP
OUTPUT (OPEN-DRAIN)
Large-Signal Differential Voltage Gain
High-Level Leakage Current (3)(4)
Low-Level Output Voltage (3)
RESPONSE TIME
Response Time
RESET
RESET Threshold
Logic Input Impedance
Minimum RESET Pulse Width
RESET Propagation Delay
(1) Hysteresis refers to the threshold (the threshold specification applies to a rising edge of a noninverting input) of a falling edge on the noninverting input of the
(2) Specified by design.
(3) V
(4) Open-drain output can be pulled to the range of +2.7V to +18V, regardless of V
Over Temperature
vs Temperature
A
comparator; refer to Figure 1.
COMPARATOR PARAMETERS
IN
IN
= +25°C, V
ID refers to the differential voltage at the comparator inputs.
Pin
Pin
(1)
(5)
S
(6)
= +12V, V
(2)
CM
= +12V, V
I
V
LKG
OL
SENSE
R
Figure 1. Typical Comparator Hysteresis
L
= 100mV, R
to 5V, C
CMP V
Input Voltage
L
Hysteresis = V
OUT
= 15pF, 100mV Input Step with 5mV Overdrive
L
V
= 10kΩ to GND, and R
1V to 4V, R
ID
V
T
A
A
ID
= −0.6V, I
= −40°C to +125°C.
CONDITIONS
= −40°C to +85°C
= 0.4V, V
T
0.592V
A
THRESHOLD
= +25°C
L
≥ 15kΩ Connected to 5V
OL
V
THRESHOLD
OH
= 2.35mA
0.6V
S
.
= V
− 8mV
S
PULL-UP
= 5.1kΩ connected from CMP
MIN
590
586
INA200, INA201, INA202
0V to V
0.0001
0.005
TYP
600
200
220
1.3
1.1
1.5
−8
OUT
S
2
3
− 1.5V
to V
S
, unless otherwise
MAX
610
614
300
www.ti.com
10
15
1
UNITS
V/mV
mV
MΩ
mV
mV
mV
nA
nA
µA
µs
µs
µs
V
V

Related parts for INA200A