ADL5592-EVALZ AD [Analog Devices], ADL5592-EVALZ Datasheet - Page 15

no-image

ADL5592-EVALZ

Manufacturer Part Number
ADL5592-EVALZ
Description
250 MHz to 2400 MHz RF Variable Gain Amplifier
Manufacturer
AD [Analog Devices]
Datasheet
EVALUATION BOARD
CHARACTERIZATION SETUP
The primary setup used to characterize the ADL5592 is shown
in Figure 23. This setup was used to measure the frequency
response, linearity, and output compression of the amplifier. A
Rohde & Schwarz SMT 03 signal generator was used to drive
the amplifier with a 4 dBm input. The output of the ADL5592
was connected to a Rohde & Schwarz FSIQ7 spectrum analyzer
through an RF switch matrix unit. For the linearity measurement,
two SMT 03 signal generators were used to generate the two-tone
RF input signal. (The same SMT 03 is used for both amplifier
SIGNAL GENERATOR
SIGNAL GENERATOR
R&S SMT 03
R&S SMT 03
TEKTRONIX DG2020A
DATA GENERATOR
DATA CLK LE
RFIN
LOIP
Figure 23. Characterization Bench Setup
ADL5592
Rev. 0 | Page 15 of 20
LOOP OUT
DC POWER SUPPLY
VCC
RFOUT
AGILENT 6624A
and mixer characterization.) The gain control data was generated
by a Tektronix DG2020A data generator. The DG2020A generated
all three of the SPI input signals: CLK, DATA, and LE. A separate
SMT 03 was used to generate the mixer local oscillator signal
(LO input signal) when the loopback mixer was enabled. An
Agilent Visual Engineering Environment (VEE) program
controlled the test instruments through the general-purpose
interface bus (GPIB) interface.
SWITCH
INSTRUMENT CONTROLLER
RF
SPECTRUM ANALYZER
GPIB INTERFACE
R&S FSIQ7
ADL5592