SDC1204-100MF SUPERWORLD [Superworld Electronics], SDC1204-100MF Datasheet - Page 3

no-image

SDC1204-100MF

Manufacturer Part Number
SDC1204-100MF
Description
SMD POWER INDUCTORS
Manufacturer
SUPERWORLD [Superworld Electronics]
Datasheet
NOTE : Specifications subject to change without notice. Please check our website for latest information.
SMD POWER INDUCTORS
6. RELIABILITY AND TEST CONDITIONS :
Electrical Characteristics Test
Inductance
DCR
Heat Rated Current (Irms)
Saturation Current (Isat)
Mechanical Performance Test
Solderability Test
Solder Heat Resistance
Reliability Test
High Temperature
Life Test
Low Temperature
Life Test
Thermal Shock
Humidity Resistance
ITEM
SUPERWORLD ELECTRONICS (S) PTE LTD
Refer to standard electrical characteristics list
More than 90% of the terminal electrode
should be covered with solder.
1. Appearance : No significant abnormality
2. Inductance change : Within ±20%
1. Appearance : No damage
2. Inductance : Within ±20% of initial value.
No disconnection or short circuit.
1. Appearance : No damage
2. Inductance : Within ±20% of initial value.
No disconnection or short circuit.
PERFORMANCE
230°C
150°C
260°C
150°C
Preheating
Preheating
seconds
seconds
60
60
Dipping
Dipping
seconds
seconds
10±0.5
4±1
Natural
cooling
Natural
cooling
HP4284A, CH11025, CH3302, CH1320, CH1320S
LCR meter.
CH16502, Agilent33420A Micro-Ohm Meter.
Irms(A) will cause the coil temperature rise
approximately
1. Applied the allowed DC current
2. Temperature measured by digital surface thermometer
Isat(A) will cause Lo to drop approximately 20% max.
Preheat : 150°C, 60sec.
Solder : Sn-Ag3.0-Cu0.5
Solder Temperature : 230±5°C
Flux for lead free : rosin
Dip Time : 4±1sec.
Preheat : 150°C, 60sec.
Solder : Sn-Ag3.0-Cu0.5
Solder Temperature : 260±5°C
Flux for lead free : rosin
Dip Time : 10±0.5sec.
Temperature : 85±5°C
Time : 500±12 hours
Measure at room temperature after placing for 2 to 3 hrs.
Temperature : -25±5°C
Time : 500±12 hours
Measure at room temperature after placing for 2 to 3 hrs.
Conditions of 1 cycle.
Measure at room temperature after placing for 2 to 3 hrs.
Temperature : 40±5°C
Humidity : 90% to 95%
Applied Current : Rated Curent
Time : 500±12 hours
Measure at room temperature after placing for 2 to 3 hrs.
Total : 5 cycles
Step
1
2
3
4
Room Temperature
Room Temperature
Temperature (°C)
TEST CONDITION
T=40°C without core loss
+85±3
-25±3
SDC1204 SERIES
Times (min.)
Within 3
Within 3
30±3
30±3
12.05.2008
PG. 3

Related parts for SDC1204-100MF