MLX90333KGO MELEXIS [Melexis Microelectronic Systems], MLX90333KGO Datasheet - Page 27

no-image

MLX90333KGO

Manufacturer Part Number
MLX90333KGO
Description
Triaxis 3D-Joystick Position Sensor
Manufacturer
MELEXIS [Melexis Microelectronic Systems]
Datasheet
14.7. Programmable Diagnostic Settings
14.7.1. RESONFAULT Parameter
This RESONFAULT parameter disables the soft reset when a fault is detected by the CPU when the
parameter is set to 1. By default, the parameter is set to “0” but it is recommended to set it to “1” to
activate the self diagnostic modes (See section 15).
Note that in the User Interface (MLX90333UI), the RESONFAULT is split in two bits:
14.7.2. EEHAMHOLE Parameter
The EEHAMHOLE parameter disables the memory recovery (Hamming code) check when a fault is
detected by the CRC when it is equal to 3131h. By default the parameter is set to 0 (enable memory
recovery).
14.8. Lock
14.8.1. MLXLOCK Parameter
MLXLOCK locks all the parameters set by Melexis.
14.8.2. LOCK Parameter
LOCK locks all the parameters set by the user. Once the lock is enabled, it is not possible to change the
EEPROM values anymore.
Note that the lock bit should be set by the solver function “MemLock”.
3901090333
Rev. Preliminary
DRESONFAULT: disable the reset in case of a fault.
DOUTINFAULT: disable output in diagnostic low in case of fault.
RESONFAULT
EEHAMHOLE
Parameter
Parameter
MLXLOCK
LOCK
Page 27 of 38
Triaxis 3D-Joystick Position Sensor
3131h
Value
Value
0
1
0
0
1
0
1
Unit
Unit
MLX90333
Data Sheet
May 07

Related parts for MLX90333KGO