MLX90316EDC ETC2 [List of Unclassifed Manufacturers], MLX90316EDC Datasheet - Page 19

no-image

MLX90316EDC

Manufacturer Part Number
MLX90316EDC
Description
Rotary Position Sensor IC
Manufacturer
ETC2 [List of Unclassifed Manufacturers]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MLX90316EDC-BCG-000-RE
Manufacturer:
INFINEON
Quantity:
101
Part Number:
MLX90316EDC-BCG-000-RE
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
15.
The MLX90316 provides numerous self-diagnostic features. Those features increase the robustness of the IC
functionality as it will prevent the IC to provide erroneous output signal in case of internal or external failure
modes (“fail-safe”).
ROM CRC Error at start up
(64 words including Intelligent
Watch Dog - IWD)
ROM CRC Error (Operation -
Background task)
RAM Test Fail (Start up)
Calibration Data CRC Error
(Start-Up)
Hamming Code Recovery Error
(Start-Up)
Calibration Data CRC Error
(Operation - Background)
Dead Zone
ADC Clipping
(ADC Output is 0000h or
7FFFh)
Radius Overflow ( > 100% ) or
Radius Underflow
( < 50 % )
Fine Gain Clipping
(FG < 0d or > 63d)
Rough Offset Clipping
(RO is < 0d or > 127d)
Rough Gain Clipping
(RG < RGTHRESLOW or RG >
RGTHRESHIGH)
DAC Monitor (Digital to Analog
converter)
ADC Monitor (Analog to Digital
converter)
MLX90316 Fault Mode continue…
3901090316
Rev. 001
MLX90316 Self Diagnostic
CPU Reset #
Enter Endless Loop:
- Progress (watchdog
Acknowledge)
- Set Outputs in Diagnostic low
CPU Reset
Hamming Code Recovery
CPU Reset
CPU Reset
Set Outputs in Diagnostic low.
Normal Operation until the “dead
zone” is left.
Set Outputs in Diagnostic low
Normal mode and CPU Reset If
recovery
Set Outputs in Diagnostic low
Normal mode and CPU Reset If
recovery
Set Outputs in Diagnostic low
Normal mode, and CPU Reset If
recovery
Set Outputs in Diagnostic low
Normal mode, and CPU Reset If
recovery
Set Outputs in Diagnostic low
Normal mode, and CPU Reset If
recovery
Set Outputs in Diagnostic low.
Normal Mode with immediate
recovery without CPU Reset
Set Outputs in Diagnostic low.
Normal Mode with immediate
recovery without CPU Reset
'*
&
Action
Page 19 of 34
Diagnostic low #
Immediate Diagnostic low
Diagnostic low
Immediate Diagnostic low
Immediate Diagnostic low
Immediate Diagnostic low
Immediate Diagnostic low
Immediate Diagnostic low
Immediate Diagnostic low
Immediate Diagnostic low
Immediate Diagnostic low
Immediate Diagnostic low
Immediate Diagnostic low
Effect on Outputs
Rotary Position Sensor IC
'+
&
All the outputs are already
in Diagnostic low - (start-up)
All the outputs are already
in Diagnostic low** ** (start-
up)
Start-Up Time is increased
by 3 ms if successful
recovery
Immediate recovery if the
“dead zone” is left
(50 % - 100 %)
No magnet / field too high
ADC Inputs are Shorted
4 October 05
Data Sheet
Remark

Related parts for MLX90316EDC