The TEST pins are not used in applications. For EMC protection it is recommended to connect the TEST
pins to Ground as close as possible to the device pins. The values for capacitors, C11, C12, C21 and C22,
can be adjusted to satisfy ESD and EMC requirements according to the environment. Ceramic capacitors
are recommended for use in the application. However for stable operation, C12 and C21 should each not be
higher than 150nF. If higher capacitors (due to special ESD or EMC requirements) or special circuit
configurations are requested, please contact Melexis.
The MLX90277 can operate with a high impedance load; a load resistor is not required.
Figures 12.1-1…12.1-2 Application Circuits
A voltage of 9V is required on V
able to withstand the voltage.
The MLX90277 is designed for operation with a stable 5V supply. If fast voltage transients occur additional
filtering may be required.
3901090277
Rev 004
12 Applications Information
12.1 Application Circuits
DD
for programming. All additional components connected to V
Page 15 of 21
Dual Programmable Linear Hall Effect Sensor
MLX90277
DD
Data Sheet
must be