AT42QT1012_10 ATMEL [ATMEL Corporation], AT42QT1012_10 Datasheet - Page 17

no-image

AT42QT1012_10

Manufacturer Part Number
AT42QT1012_10
Description
One-channel Toggle-mode Touch Sensor IC with Power Management Functions
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet
3.11.5
9543D–AT42–08/10
Auto Off – Overriding the Auto Off Delay
In normal operation the QT1012 output is turned off automatically after the auto-off delay. In
some applications it may be useful to extend the auto-off delay (“sustain” function) or to switch
the output off immediately (“cancel” function). This can be achieved by pulsing the voltage on
the delay multiplier resistor Rm as shown in
To ensure the pulse is detected it must be present for typical times as shown in
Table 3-6.
While Vm is held in the override state the QT1012 inhibits bursts and waits for Vm to return to its
original state. When Vm returns to its original state the QT1012 performs a sensor recalibration
before continuing in its current output state.
Figure 3-11. Override Pulse (Delay Multiplier x1)
Pulse Duration
tp – series of short pulses, typically 65 ms
tp – long pulse, typically 250 ms
Time Delay Pulse
VDD
VSS
Vm
ELECTRODE
Tp
SENSE
RS
CS
Rm
4
3
SNS
SNSK
VDD
VDD
VSS
5
2
Action
“Sustain”/retrigger (reload auto-off delay counter)
“Cancel”/switch output to off state and inhibit further
touch detection until Vm returns to original state
Figure 3-11
TIME
OUT
1
6
and
Rop
Figure 3-12 on page
AT42QT1012
Table
18.
3-6.
17

Related parts for AT42QT1012_10