PEB2465 SIEMENS [Siemens Semiconductor Group], PEB2465 Datasheet - Page 29

no-image

PEB2465

Manufacturer Part Number
PEB2465
Description
Four Channel Codec Filter
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2465
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2465
Manufacturer:
AD
Quantity:
5 510
Part Number:
PEB2465H
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2465H
Manufacturer:
CY
Quantity:
5 510
Part Number:
PEB2465H V2.4
Manufacturer:
EPCOS
Quantity:
11 200
Part Number:
PEB2465H-V2.3
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2465H-V2.3
Manufacturer:
SIE
Quantity:
20 000
Part Number:
PEB2465HV2.4
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
3.4
To modify or evaluate the SICOFI-4 status, the contents of up to four configuration
registers CR1, CR2, CR3 and CR4 may be transferred to or from the SICOFI-4. This is
started by a SOP-Command (status operation command).
Bit
AD
RW
PWRUP
LSEL
All other codes are reserved for future use!
It is possible to program each Configuration register separately, just by putting only one
byte into the FIFO of the upstream master device (e.g. EPIC), and aborting after
transmission of one (or n) byte.
Semiconductor Group
7
SOP Command
AD
Address Information
AD = 0
AD = 1
Read/Write Information: Enables reading from the SICOFI-4 or writing
information to the SICOFI-4
RW = 0
RW = 1
Power Up / Power Down
PWRUP = 1
PWRUP = 0
Length select information (see also Programming Procedure, page 74)
This field identifies the number of subsequent data bytes
LSEL = 000
LSEL = 001
LSEL = 010
LSEL = 011
LSEL = 100
6
RW
5
PWRUP
0 bytes of data are following
1 byte of data is following (CR1)
2 bytes of data are following (CR2, CR1)
3 bytes of data are following (CR3, CR2, CR1)
4 bytes of data are following (CR4, CR3, CR2, CR1)
SICOFI-4 channel 1(3) is addressed with this command
SICOFI-4 channel 2(4) is addressed with this command
Write to SICOFI-4
Read from SICOFI-4
sets the assigned channel (see bit AD) of SICOFI-4 to
power-up (operating mode)
resets the assigned channel of SICOFI-4 to power-down
(standby mode)
4
1
29
3
0
2
Programming the SICOFI
LSEL2
1
LSEL1
PEB 2465
0
LSEL0
02.97
®
-4

Related parts for PEB2465