PIC18F2420 MICROCHIP [Microchip Technology], PIC18F2420 Datasheet - Page 95

no-image

PIC18F2420

Manufacturer Part Number
PIC18F2420
Description
28/40/44-Pin Enhanced Flash Microcontrollers with 10-Bit A/D and nanoWatt Technology
Manufacturer
MICROCHIP [Microchip Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F2420-E/SP
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F2420-I/ML
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F2420-I/SO
Manufacturer:
MICROCHIP
Quantity:
1 560
Part Number:
PIC18F2420-I/SO
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
PIC18F2420-I/SO
0
Part Number:
PIC18F2420-I/SP
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
9.1
The INTCON registers are readable and writable
registers, which contain various enable, priority and
flag bits.
REGISTER 9-1:
 2004 Microchip Technology Inc.
INTCON Registers
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
INTCON REGISTER
bit 7
GIE/GIEH: Global Interrupt Enable bit
When IPEN = 0:
1 = Enables all unmasked interrupts
0 = Disables all interrupts
When IPEN = 1:
1 = Enables all high priority interrupts
0 = Disables all interrupts
PEIE/GIEL: Peripheral Interrupt Enable bit
When IPEN = 0:
1 = Enables all unmasked peripheral interrupts
0 = Disables all peripheral interrupts
When IPEN = 1:
1 = Enables all low priority peripheral interrupts
0 = Disables all low priority peripheral interrupts
TMR0IE: TMR0 Overflow Interrupt Enable bit
1 = Enables the TMR0 overflow interrupt
0 = Disables the TMR0 overflow interrupt
INT0IE: INT0 External Interrupt Enable bit
1 = Enables the INT0 external interrupt
0 = Disables the INT0 external interrupt
RBIE: RB Port Change Interrupt Enable bit
1 = Enables the RB port change interrupt
0 = Disables the RB port change interrupt
TMR0IF: TMR0 Overflow Interrupt Flag bit
1 = TMR0 register has overflowed (must be cleared in software)
0 = TMR0 register did not overflow
INT0IF: INT0 External Interrupt Flag bit
1 = The INT0 external interrupt occurred (must be cleared in software)
0 = The INT0 external interrupt did not occur
RBIF: RB Port Change Interrupt Flag bit
1 = At least one of the RB7:RB4 pins changed state (must be cleared in software)
0 = None of the RB7:RB4 pins have changed state
Legend:
R = Readable bit
-n = Value at POR
GIE/GIEH
Note:
R/W-0
A mismatch condition will continue to set this bit. Reading PORTB will end the
mismatch condition and allow the bit to be cleared.
PEIE/GIEL
R/W-0
PIC18F2420/2520/4420/4520
Preliminary
TMR0IE
R/W-0
W = Writable bit
‘1’ = Bit is set
INT0IE
R/W-0
Note:
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
R/W-0
Interrupt flag bits are set when an interrupt
condition occurs, regardless of the state of
its corresponding enable bit or the global
enable bit. User software should ensure
the appropriate interrupt flag bits are clear
prior to enabling an interrupt. This feature
allows for software polling.
RBIE
TMR0IF
R/W-0
x = Bit is unknown
INT0IF
R/W-0
DS39631A-page 93
R/W-x
RBIF
bit 0

Related parts for PIC18F2420