signal Vmemory is a signal that switches between a low voltage (3.5 – 5.5V) and a
high voltage (5-6V). The signal Mem_hl controls the applied level and the power
supply lines Vmem_l and Vmem_h determine the low and high dc-levels.
The Reset signal is due to the dual slope technique a little more complex. In case the
dual slope is not used, the reset signal is straightforward generated from the external
reset pulse. In this case the supply voltage Vres determines the level to which the
pixel is resetted.
In case the dual slope operation is desired, one needs to give a second pulse to a lower
reset level during integration. This can be done by the control signal Reset_ds and by
the power supply Vres_ds that defines the level to which the pixel has to be resetted.
If a pulse is given on the Reset_ds signal, a second pulse on the internal reset line is
generated to a lower level, determined by the supply Vres_ds. If no Reset_ds pulse is
given, the dual slope technique is not implemented.
Note that Reset is dominant over Reset_ds, which means that the high voltage level
will be applied for reset, if both pulses occur at the same time.
The external control signals should be capable of driving input capacitance of about
20pF.
3.8.4 Digital signals
The digital signals control the readout of the image sensor. These signals are:
Cypress Semiconductor Corporation
Contact info@Fillfactory.com
• Sync_y: Starts the readout of the frame or window at the address defined by
• Clock_y: Clock of the y-register. On the rising edge of this clock, the next
• Sync_x: Starts the readout of the selected line at the address defined by the x-
• Address: the x- and y-address is downloaded serial through this signal.
• Clock_spi: clock of the serial parallel interface. This clock downloads the
• Load_addr: when the SPI register is downloaded with the desired address, the
• Sh_col: control signal of the column readout. Is only used in sample & hold
• Norow_sel: Control signal of the column readout. Is only used in Norow_sel
• Pre_col: Control signal of the column readout to reduce row blanking time
• Sel_active: activates the active load on chip for the output amplifiers. If not
LUPA-1300
Datasheet
the y-address register. This pulse synchronizes the y-address register: active
high. This signal is at the same time the end of the frame or window and
determines the window width.
line is selected.
address register. This pulse synchronizes the x-address register: active high.
This signal is at the same time the end of the line and determines the window
length.
address into the SPI register.
signal Load_addr signal loads the x-and y-address into their address register as
starting point of the window of interest.
mode (See timing)
mode ( See timing)
used, a passive load can be used or one can use this signal to put the output