908E624 ANALOG DIE MODES OF OPERATION
Stop, and Sleep. In Normal mode the device is active and is
operating under normal application conditions. The Stop and
Sleep modes are low-power modes with wake-up
capabilities.
with V
voltage regulator is turned off (V
Analog Integrated Circuit Device Data
Freescale Semiconductor
The 908E624 offers three operating modes: Normal (Run),
In Stop mode the voltage regulator still supplies the MCU
DD
Legend
WD: Watchdog
WD Disabled: Watchdog disabled (WDCONF terminal connected to GND)
WD Trigger: Watchdog is triggered by SPI command
WD Failed: No watchdog trigger or trigger occurs in closed window
Stop Command: Stop command sent via SPI
Sleep Command: Sleep command sent via SPI
Wake-Up: L1 or L2 state change or LIN bus wake-up or SS rising edge
(limited current capability) and in Sleep mode the
Power
Down
Notes:
WD - means Watchdog
WD disabled - means Watchdog disabled (WDCONF terminal connected to GND)
WD trigger – means Watchdog is triggered by SPI command
WD failed – means no Watchdog trigger or trigger occurs in closed window
STOP Command - means STOP command sent via SPI
SLEEP Command - means SLEEP command send via SPI
Wake-Up - means L1 or L2 state change or LIN bus wake up or SS rising edge
Power Up
DD
= 0 V).
FUNCTIONAL DEVICE OPERATION
Figure 11. Operating Modes and Transitions
Reset
Wake-Up (Reset)
Wake-Up (Reset)
OPERATIONAL MODES
V
V
DD
DD
Normal Request Timeout Expired (t
Low (>NR
LOW (>t
and VSUV = 0
and LVF = 0
TOUT
Normal Request timeout expired (NR
V
NRTOUT
Reset Delay (t
DD
) expired
High and Reset Delay (t
interrupt. Wakeup from Sleep mode is done by a reset and
the voltage regulator is turned back on.
MODE1:2 bits in the SPI Control register.
different operating modes and
overview of the operating mode.
V
V
) Expired
WD Failed
DD
DD
V
V
Wake-up from Stop mode is initiated by a wake-up
The selection of the different modes is controlled by the
Figure 11
WD failed
DD
V
V
Sleep
V
DD
High and
DD
DD
Low
Low
DD
Low
Low
Low
Low
RST
) Expired
RST
Sleep Command
describes how transitions are done between the
) expired
SLEEP Command
NRTOUT
TOUT
)
)
FUNCTIONAL DEVICE OPERATION
Request
Normal
Normal
Table
Stop
6, page 22, gives an
OPERATIONAL MODES
908E624
21