EPM3256A ALTERA [Altera Corporation], EPM3256A Datasheet - Page 10

no-image

EPM3256A

Manufacturer Part Number
EPM3256A
Description
Programmable Logic Device Family
Manufacturer
ALTERA [Altera Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EPM3256A144-10N
Manufacturer:
ALTERA
0
Part Number:
EPM3256AC144-10N
Manufacturer:
ALTERA
0
Part Number:
EPM3256ACT144-7
Manufacturer:
ALTERA
0
Part Number:
EPM3256AEFC256
Manufacturer:
ALTERA
0
Part Number:
EPM3256AETC100
Manufacturer:
ALTERA
0
Part Number:
EPM3256AF1256-10
Quantity:
5 510
Part Number:
EPM3256AF1256-10
Manufacturer:
ATMEL
Quantity:
5 510
Part Number:
EPM3256AFC256-10
Manufacturer:
ALTERA
Quantity:
12 388
Part Number:
EPM3256AFC256-10
Manufacturer:
ALTERA
Quantity:
917
Part Number:
EPM3256AFC256-10
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EPM3256AFC256-10N
0
Part Number:
EPM3256AFC256-7
Quantity:
1 097
MAX 3000A Programmable Logic Device Family Data Sheet
10
Programmable Interconnect Array
Logic is routed between LABs on the PIA. This global bus is a
programmable path that connects any signal source to any destination on
the device. All MAX 3000A dedicated inputs, I/O pins, and macrocell
outputs feed the PIA, which makes the signals available throughout the
entire device. Only the signals required by each LAB are actually routed
from the PIA into the LAB.
into the LAB. An EEPROM cell controls one input to a two-input AND gate,
which selects a PIA signal to drive into the LAB.
Figure 5. MAX 3000A PIA Routing
While the routing delays of channel–based routing schemes in masked or
FPGAs are cumulative, variable, and path–dependent, the MAX 3000A
PIA has a predictable delay. The PIA makes a design’s timing
performance easy to predict.
I/O Control Blocks
The I/O control block allows each I/O pin to be individually configured
for input, output, or bidirectional operation. All I/O pins have a tri–state
buffer that is individually controlled by one of the global output enable
signals or directly connected to ground or V
control block for MAX 3000A devices. The I/O control block has 6 or
10 global output enable signals that are driven by the true or complement
of two output enable signals, a subset of the I/O pins, or a subset of the
I/O macrocells.
PIA Signals
Figure 5
shows how the PIA signals are routed
CC
.
Figure 6
Altera Corporation
shows the I/O
To LAB