MAX691A MAXIM [Maxim Integrated Products], MAX691A Datasheet - Page 15
MAX691A
Manufacturer Part Number
MAX691A
Description
Microprocessor Supervisory Circuits
Manufacturer
MAXIM [Maxim Integrated Products]
Datasheet
1.MAX691A.pdf
(16 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
MAX691A
Manufacturer:
MAXIM
Quantity:
5 510
Part Number:
MAX691ACPE
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
MAX691ACPE+
Manufacturer:
Maxim
Quantity:
925
Company:
Part Number:
MAX691ACSE
Manufacturer:
MAXIM
Quantity:
21
Company:
Part Number:
MAX691ACSE
Manufacturer:
MAIXM
Quantity:
16
Part Number:
MAX691ACSE
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX691ACSE+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
MAX691ACSE+T
Manufacturer:
MAXIM
Quantity:
3 400
Part Number:
MAX691ACSE+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX691ACWE
Manufacturer:
MAXIM/美信
Quantity:
20 000
The V
the battery switchover comparator and should not
exceed 0.03V/µs. A standard rule of thumb for filter
capacitance on most regulators is on the order of 100µF
per amp of current. When the power supply is shut off or
the main battery is disconnected, the associated initial
V
The V
nentially, which more than satisfies the maximum fall-time
requirement.
A way to help the watchdog timer keep a closer watch
on software execution involves setting and resetting the
watchdog input at different points in the program,
rather than “pulsing” the watchdog input high-low-high
or low-high-low. This technique avoids a “stuck” loop
where the watchdog timer continues to be reset within
the loop, keeping the watchdog from timing out. Figure
14 shows an example flow diagram where the I/O dri-
ving the watchdog input is set high at the beginning of
the program, set low at the beginning of every subrou-
tine or loop, then set high again when the program
returns to the beginning. If the program should “hang”
in any subroutine, the I/O is continually set low and the
watchdog timer is allowed to time out, causing a reset
or interrupt to be issued.
CC
fall rate is just the inverse or 1A/100µF = 0.01V/µs.
CC
CC
fall rate decreases with time as V
fall time is limited by the propagation delay of
Watchdog Software Considerations
______________________________________________________________________________________
Maximum V
Microprocessor Supervisory Circuits
CC
CC
Fall Time
falls expo-
Figure 14. Watchdog Flow Diagram
OR PROGRAM LOOP
SUBROUTINE
SET WDI
RETURN
START
LOW
HIGH
END
WDI
SET
15