MAX5028 MAXIM [Maxim Integrated Products], MAX5028 Datasheet

no-image

MAX5028

Manufacturer Part Number
MAX5028
Description
RELIABILITY REPORT FOR MAX5026EUT PLASTIC ENCAPSULATED DEVICES
Manufacturer
MAXIM [Maxim Integrated Products]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX5028EUT+
Manufacturer:
MAXIM
Quantity:
665
Part Number:
MAX5028EUT+T
Manufacturer:
MAXIM
Quantity:
1 215
MAX5026EUT
Rev. A
RELIABILITY REPORT
FOR
MAX5026EUT
PLASTIC ENCAPSULATED DEVICES
March 12, 2003
MAXIM INTEGRATED PRODUCTS
120 SAN GABRIEL DR.
SUNNYVALE, CA 94086
Written by
Reviewed by
Jim Pedicord
Bryan J. Preeshl
Quality Assurance
Quality Assurance
Reliability Lab Manager
Executive Director

Related parts for MAX5028

MAX5028 Summary of contents

Page 1

RELIABILITY REPORT PLASTIC ENCAPSULATED DEVICES MAXIM INTEGRATED PRODUCTS 120 SAN GABRIEL DR. SUNNYVALE, CA 94086 Written by Jim Pedicord Quality Assurance Reliability Lab Manager FOR MAX5026EUT March 12, 2003 Bryan J. Preeshl Quality Assurance Executive Director MAX5026EUT Rev. A Reviewed ...

Page 2

The MAX5026 successfully meets the quality and reliability standards required of all Maxim products. In addition, I. ........Device Description II. ........Manufacturing Information III. .......Packaging Information A. General The MAX5026 constant-frequency, pulse-width modulating (PWM), low-noise boost converter is intended for low- ...

Page 3

A. Description/Function: B. Process: C. Number of Device Transistors: D. Fabrication Location: E. Assembly Location: F. Date of Initial Production: A. Package Type: B. Lead Frame: C. Lead Finish: D. Die Attach: E. Bondwire: F. Mold Material: G. Assembly Diagram: ...

Page 4

A. Quality Assurance Contacts: B. Outgoing Inspection Level: C. Observed Outgoing Defect Rate: < 50 ppm D. Sampling Plan: Mil-Std-105D A. Accelerated Life Test The results of the 135 C biased (static) life test are shown in Table 1. Using ...

Page 5

TEST CONDITION Ta = 135 C Biased Time = 192 hrs. Pressure Pot Ta = 121 psi. RH= 100% Time = 168hrs. 85/ 85% Biased Time = 1000hrs. Temperature -65 ...

Page 6

TABLE II. Pin combination to be tested (Each pin individually connected to terminal A with the other floating) All pins except V 1. All input and output pins 2. 1/ Table II is restated in narrative form in ...

Page 7

...

Page 8

OHMS 10K OHMS DEVICES: MAX 5025/26/27/28 MAX. EXPECTED CURRENT = +15 (1 mA); -15 (2mA); -20V(3mA) DOCUMENT I.D. 06-5729 REVISION A ONCE PER SOCKET 10K OHMS 1 PGND SHNB 4 0.1 ...