IDTQS3VH257 Integrated Device, IDTQS3VH257 Datasheet - Page 5

no-image

IDTQS3VH257

Manufacturer Part Number
IDTQS3VH257
Description
QUICKSWITCH PRODUCTS 2.5V/3.3V QUAD 2:1 MUX/DEMUX HIGH BAND WIDTH BUS SWITCH
Manufacturer
Integrated Device
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
IDTQS3VH257PA
Quantity:
4 954
Part Number:
IDTQS3VH257PAG
Manufacturer:
IDT
Quantity:
20 000
Part Number:
IDTQS3VH257PAG8
Manufacturer:
IDT Integrated Device Technolo
Quantity:
40 675
Part Number:
IDTQS3VH257Q
Manufacturer:
IDT
Quantity:
15
Part Number:
IDTQS3VH257Q
Manufacturer:
datel
Quantity:
11
Part Number:
IDTQS3VH257Q
Manufacturer:
IDT
Quantity:
20 000
Part Number:
IDTQS3VH257QG
Manufacturer:
IDT20
Quantity:
513
Part Number:
IDTQS3VH257QG
Manufacturer:
IDT
Quantity:
20 000
Part Number:
IDTQS3VH257QG8
Manufacturer:
IDT Integrated Device Technolo
Quantity:
32 407
Part Number:
IDTQS3VH257QG8
Manufacturer:
IDT
Quantity:
20 000
Company:
Part Number:
IDTQS3VH257QG8
Quantity:
190
Part Number:
IDTQS3VH257S1
Manufacturer:
IDT
Quantity:
6
SWITCHING CHARACTERISTICS OVER OPERATING RANGE
T
NOTES:
1. See Test Conditions under TEST CIRCUITS AND WAVEFORMS.
2. This parameter is guaranteed but not production tested.
3. The bus switch contributes no propagation delay other than the RC delay of the ON resistance of the switch and the load capacitance. The time constant for the switch alone
4. Minimums are guaranteed but not production tested.
5. Maximum toggle frequency for S or E control input (pass voltage > V
IDTQS3VH257
2.5V / 3.3V QUAD 2:1 MUX/DEMUX HIGH BANDWIDTH BUS SWITCH
A
Symbol
= -40°C to +85°C
is of the order of 0.2ns at C
system. Propagation delay of the bus switch, when used in a system, is determined by the driving circuit on the driving side of the switch and its interaction with the load on
the driven side.
f
t
t
t
t
t
t
t
t
t
t
t
EorS
PLH
PHL
SEL
PZH
PZL
PHZ
PLZ
PZH
PZL
PHZ
PLZ
Parameter
Data Propagation Delay
Yx to Ixx or Ixx to Yx
Select Time
S to Yx
Enable Time
S to Ixx
Disable Time
S to Ixx
Enable Time
E to Yx or Ixx
Disable Time
E to Yx or Ixx
Operating Frequency - Enable
L
= 50pF. Since this time constant is much smaller than the rise and fall times of typical driving signals, it adds very little propagation delay to the
(2,3)
(2,5)
Min
1.5
1.5
1.5
1.5
1.5
.
CC
(4)
V
, V
CC
IN
= 2.5 ± 0.2V
= 5V, R
5
LOAD
(1)
≥ 1MΩ, no C
Max.
0.2
10
9
9
8
9
8
LOAD
).
Min
1.5
1.5
1.5
1.5
1.5
.
(4)
V
CC
INDUSTRIAL TEMPERATURE RANGE
= 3.3 ± 0.3V
(1)
Max.
0.2
20
8
9
8
8
8
MHz
Unit
ns
ns
ns
ns
ns
ns

Related parts for IDTQS3VH257