TCL TRACOPOWER [TRACO Electronic AG], TCL Datasheet - Page 2

no-image

TCL

Manufacturer Part Number
TCL
Description
Industrial Power Supplies ( TCL Series, 24 - 120 Watt)
Manufacturer
TRACOPOWER [TRACO Electronic AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TCL-A05V02-PA
Manufacturer:
SANYO/三洋
Quantity:
20 000
Part Number:
TCL-A08V04
Manufacturer:
SANYO/三洋
Quantity:
20 000
Part Number:
TCL-A14V02-TO
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
TCL-A27V02-T0
Manufacturer:
UNICHIP
Quantity:
238
Part Number:
TCL-A27V02-T0
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
TCL-H13V03-TO
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
TCL-M11V1P
Manufacturer:
TCL
Quantity:
24
Part Number:
TCL-M11V3P-M6S
Manufacturer:
TCL
Quantity:
161
Part Number:
TCL-M12V1P
Manufacturer:
infineon
Quantity:
137
Part Number:
TCL-M16V2-S
Manufacturer:
TCL
Quantity:
459
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Input Specifications
Input voltage range
output derating at operation between 85...93VAC/85...130VDC:
Input frequency
Harmonic limits
Input current at full load (typ.)
Recommended circuit breaker (characteristic C or slow blow fuse)
Output Specifications
Output voltage adj. range
(pot.meter on frontpanel)
Output regulation (10 to 90% load variation)
Ripple and Noise (20MHz Bandwidth)
Electronic short circuit protection
Parallel operation
Overvoltage protection, triggerpoint
Hold-up time
Power good signal (TCL 60 & TCL 120 only)
General Specifications
Temperature ranges
Temperature derating
Humidity (non condensing)
Temperature coefficient
Switching frequency
Efficiency
Isolation
Reliability, calculated MTBF @ 25°C
(according to IEC- 1 709)
– Operating
– Storage (non operating)
– at 187 ...264 VAC or 265...375 VDC operation
– at 93...132 VAC or 130...187 VDC operation
– at 85...130 VDC operation
12 / 24 VDC models: < 40 VDC
TCL 120 models: 2.0 A
24 VDC models: 24 – 28 VDC
48 VDC models: 48 – 56 VDC
48 VDC models: < 60 VDC
24 VDC models: >22V
48 VDC models: >44V
TCL 120 models: >1.62 Mio h
12 VDC models: 12 – 15 VDC (12 - 16 VDC for TCL 024- 1 12)
12 VDC models: >11V
5.1 VDC model: 5.0 – 5.25 VDC
5.1 VDC model: < 6.5 VDC
TCL 60 models: 1.2 A
TCL 60 models: >2.94 Mio h
TCL 24 models: 0.35 A
TCL 24 models: >2.68 Mio h
Industrial Power Supplies
TCL Series
85...264 VAC / 85...375 VDC
15% for TCL 060 & TCL 120 models
20% for TCL 024-112 & TCL 024-124
30% for TCL 024-105
47 – 63 Hz
EN610000-3-2 Class A
115 VAC
5.0 A
2.5% (1% for TCL 60-112)
< 50 mV pk-pk
current limitation at 120 % typ
(constant current, automatic recovery
TCL 24 models: foldback, automatic recovery)
output current characteristic suitable for
parallel operation of max. 5 units
min. 15 ms
trigger
point
– 10 °C…+70 °C max.
– 25 °C…+85 °C
1.7% /K above 50°C
1.1% /K above 40°C
1.3% /K above 30°C
95 % rel. H max.
0.02 % /K
55 – 180 kHz depending on load
(frequency modulation)
88% typ.
according to IEC/EN 60950, UL 60950,
UL 508, EN 50178, EN 60204, EN 61558-2-8
115 VAC
230 VAC
0.2 A
0.6 A
1.0 A
230 VAC
min. 125 ms
output signal
(reference to – Vout)
11.0 V ±1.0V / 60 mA max.
22.0 V ±2.0V / 30 mA max.
44.0 V ±4.0V / 15 mA max.
24–120 Watt
Page 2 of 5