LTC1092 LINER [Linear Technology], LTC1092 Datasheet - Page 22

no-image

LTC1092

Manufacturer Part Number
LTC1092
Description
1-, 2-, 6- and 8-Channel, 10-Bit Serial I/O Data Acquisition Systems
Manufacturer
LINER [Linear Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC1092
Manufacturer:
LT
Quantity:
5 510
Part Number:
LTC1092
Manufacturer:
LT
Quantity:
5 510
Part Number:
LTC1092ACN8
Quantity:
2 000
Part Number:
LTC1092ACN8#PBF
Quantity:
2 000
Part Number:
LTC1092CN8
Manufacturer:
LT
Quantity:
2 000
Part Number:
LTC1092CSW
Manufacturer:
LINEAR/凌特
Quantity:
20 000
“–” Input Settling
At the end of the sample phase the input capacitor switches
to the “–” input and the conversion starts (see Figure 8).
During the conversion, the “+” input voltage is effectively
“held” by the sample-and-hold and will not affect the
conversion result. However, it is critical that the “–” input
voltage settle completely during the first CLK cycle of the
conversion time and be free of noise. Minimizing R
and C2 will improve settling time. If large “–” input source
resistance must be used, the time allowed for settling can
be extended by using a slower CLK frequency. At the
maximum CLK rate of 500kHz, R
C2 < 20pF will provide adequate settling.
A
22
LTC1091/LTC1092
LTC1093/LTC1094
“+” INPUT
“–” INPUT
PPLICATI
D
CLK
OUT
D
CS
IN
O
U
S
I FOR ATIO
U
START
SOURCE
W
Figure 8. “+” and “–” Input Settling Windows
SGL/DIFF
< 1k
U
SOURCE
and
Input Op Amps
When driving the analog inputs with an op amp it is
important that the op amp settle within the allowed time
(see Figure 8). Again, the “+” and “–” input sampling times
can be extended as previously described to accommodate
slower op amps. Most op amps, including the LT1006 and
LT1013 single supply op amps, can be made to settle well
even with the minimum settling windows of 3 s (“+”
input) and 2 s (“–” input) which occur at the maximum
clock rate of 500kHz. Figures 9 and 10 show examples of
adequate and poor op amp settling.
1ST BIT TEST “–” INPUT MUST
SAMPLE
SETTLE DURING THIS TIME
“+” INPUT MUST
SETTLE DURING
THIS TIME
MSBF
t
SMPL
HOLD
DON‘T CARE
t
CONV
1091-4 F08
B9

Related parts for LTC1092