User's Guide
Combination IR + Stem
Thermometer
Model IR301
Introduction
Specifications
Display
Thermocouple probe
Measurement ranges
Resolution
Accuracy
IR Distance/Spot ratio 1:1 (the meter’s distance from object
Out of range indicators ‘ ’ or ‘
Low battery indication
EMC/FRI
Power supply
Battery life
Dimensions
Weight
Congratulations on your purchase of the Extech IR301. The
IR301 is a combination non-contact infrared thermometer and
probe thermometer. Careful use of this instrument will provide
years of reliable service.
2000 count Dual LCD display.
4.5” (114mm) stainless steel stem type K
Non-contact Infrared (IR) mode:
-27 to 428
Contact temperature probe mode:
-67 to 626
0.1
IR: ±3% of reading or 6
Probe: ±1% of reading or 2
* whichever is greater
equals the size of the measurement spot)
Readings may be affected if the unit is
operated within radio frequency
electromagnetic field strengths of 3V per
meter (approx.). Note that the meter will
not be permanently affected.
CR2032 button battery
30 hours of continuous use (minimum)
1.0 x 1.6 x 6.1" (24.2 x 39.8 x 156mm)
Approx. 2.6 oz. (70g) with battery
o
to 199.9
’ appears on the LCD
o
o
F (-33 to 220
F (-55 to 330
o
; 1
o
>200
o
o
o
F (3
C)
C)
o
F (1.2
o
C)*
o
C)*
Meter Description
Operation
Non-contact InfraRed (IR) Temperature Measurements
Contact Temperature Probe Measurements
1. Aim the meter’s IR lens (top of meter) toward the
2. Press and hold the IR button to continuously
3. When the IR button is released, the HOLD
4. The meter will automatically turn OFF after
1. Carefully release the probe from its latch and
2. Press the PROBE button momentarily to begin
3. Press the PROBE button again to hold the
4. The meter will automatically turn OFF after
5. Keep the probe in the latched position when not
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Infrared sensor
Note that the battery compartment is located on the rear of
the instrument.
surface under test; hold the meter as close as
safely possible to the surface under test.
measure temperature. The IR measurement
reading appears on the upper display.
display icon switches on, indicating that the last
reading is now being held (frozen).
approximately 10 seconds.
rotate it to the desired position. Do NOT attempt
to rotate the probe arm more than 180
taking readings. The lower display will indicate
the measured temperature.
reading. The HOLD icon will switch on indicating
that the reading is held (frozen). Press the
PROBE button again to exit the HOLD mode.
approximately 4 minutes.
in use.
Probe Holder
Probe
Probe swivel arm
IR display
Pocket clip
Probe display
IR button
MODE button
Thermocouple probe button
o
.
o
Minimum / Maximum IR Readings (IR measurements only)
IR Lock Mode
IR Emissivity Adjustment
C /
The IR301 has a factory default emissivity setting of 0.95. This
is the best setting for most applications. However, for some
surfaces, this setting may require adjustment. Emissivity tables
are available which include most common materials. To
determine the proper emissivity setting for any surface, take a
probe measurement and an IR measurement of the surface. If
the readings match, the emissivity setting is correct. If the
readings are different, the emissivity should be adjusted until
the IR reading agrees with the probe measurement.
To adjust the emissivity, press the IR button once and then
press the MODE button five (5) times. Now use the IR button to
scroll through the emissivity selection range.
The emissivity range is 0.1 to 1.00 (the IR301 display actually
shows 10 to 100 representing 0.1 to 1.00).
To exit this mode, press and hold the MODE button.
1. The MIN and MAX modes allow the user to take
2. Press the IR button to turn on the IR measurement mode
3. Press the MODE button once to select the flashing “MIN”
4. Press and hold the IR button to take a continuous IR
5. To exit this mode, press and hold the MODE button.
1. In the LOCK mode, the user can take a continuous IR
2. Press the IR button, press the MODE button three (3) times
3. The meter will now measure temperature continuously for
o
F Temperature units selection
To change the temperature units press the IR button once,
the MODE button four (4) times, & the IR button once again.
measurements while only viewing the highest (MAX) or
lowest (MIN) reading.
icon or press the MODE button twice to select the flashing
“MAX” icon.
measurement. As long as the IR button is held down, only
the lowest (MIN) or the highest (MAX) reading will display.
Subsequent measurements will only update the display if a
lower or higher reading is encountered.
measurement (for up to 60 minutes) without having to press
and hold the IR button.
and then press the IR button again. The “LOCK” display
icon will appear on the LCD.
up to 60 minutes or until the IR button is pressed.

Related parts for IR301

IR301 Summary of contents

Page 1

... The meter will now measure temperature continuously for minutes or until the IR button is pressed. IR Emissivity Adjustment The IR301 has a factory default emissivity setting of 0.95. This is the best setting for most applications. However, for some surfaces, this setting may require adjustment. Emissivity tables are available which include most common materials ...

Page 2

... Replace the CR2032 battery (+ side out) and replace the cover. Storage and Cleaning The IR lens is the most delicate part of the IR301; the lens should be kept clean at all times. Care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or isopropyl alcohol ...